Mechanical data:
solid Shaft
ø58 mm Clamp ø12 mm Shaft
Interface:SSI with Preset
Transmission Rate min. 20 kBaud, max. 1 MBaud
Interface Cycle Time: > 1 ms
Electrical Data:
Supply Voltage 4.75 – 30 VDC (On power supplies comply with EN 50178)
Current Consumption Typical 50 mA
Power Consumption ≤ 1.5 W
Start-Up Time < 250 ms
Clock Input RS 422, via Optocoupler
Clock Frequency 100 kHz – 2 MHz
Reverse Polarity Protection Yes