Feature OF IE5382
Extended sensing range reduces failures from mechanical damage
Durable special-coated brass housing
Certain models operate as PNP or NPN for versatile wiring solutions
Optional 300 mm cable with M12 Micro DC connector for mounting flexibility
Industry standard M12 Micro DC connector
Product characteristics
Inductive sensor
Metal thread M8 x 1
Quick disconnect
Sensing range 4 mm; [nf] non-flush mountable
Electrical data
Electrical design
DC PNP
Operating voltage [V]
10...36 DC (PELV)
Current consumption [mA]
< 15
Protection class
III
Reverse polarity protection
yes
Outputs
Output function
normally open
Voltage drop [V]
< 2.5
Current rating [mA]
200
Short-circuit protection
Yes (non-latching)
Overload protection
yes
Switching frequency [Hz]
700
Monitoring range
Sensing range [mm]
4
Real sensing range (Sr) [mm]
4 10 %
Operating distance [mm]
0...3.25
Accuracy / deviations
Correction factors
mild steel = 1 / stainless steel approx. 0.7 / brass approx. 0.5 / aluminium approx. 0.4 / copper approx. 0.3
Hysteresis [% of Sr]
1...15
Switch-point drift [% of Sr]
-10...10
Environment
Ambient temperature [C]
-25...70
Protection
IP 67
Tests / approvals
EMC
EN 60947-5-2
MTTF [Years]
2751
Mechanical data
Mounting
non-flush mountable
Housing materials
housing: high-grade stainless steel; active face: LCP