Add To Cart
share
SICK IQ80-60NPP-KK0 Overview
Inductive proximity sensor IQ80-60NPP-KK0 Sn 60mm, unshielded, terminal chamber DC 3-wire, PNP, programmable
SICK IQ80-60NPP-KK0 Description
- Operating distance adjustable from 20 mm to 60 mm
- Programmable N/O or N/C function
- Terminal or M12 connection
- DC and AC/DC versions available
- Increased machine throughput with less machine downtime
- Maintenance cost reduction and reduced mechanical damage due to long sensing range
- Reduced maintenance cost due to longer service life
- Time-saving quick and easy installation
Your benefits
| Features | |
| Sensing range Sn: | 60 mm |
| Installation in metal: | Non-flush |
| Switching frequency: | 100 Hz |
| Connection type: | Terminal connection with M20 gland |
| Switching output: | PNP |
| Output function: | NCC or NOCNCC or NOC |
| Electrical wiring: | DC 3-wire |
| Enclosure rating: | IP 65 1) |
| Switching mode: | NCC or NOCNCC or NOC |
| 1) According to EN60529 | |
| Mechanics/electronics | |
| Design: | cuboid |
| Supply voltage: | 10 V DC ... 36 V DC |
| Power consumption: | ≤ 15 mA 1) |
| Voltage drop: | ≤ 2.5 V 2) |
| Continuous current Ia: | ≤ 250 mA |
| Hysteresis: | 1 % ... 15 % |
| Temperature drift (of sr):: | 10 % |
| EMC: | According to EN 60947-5-2 |
| Reverse polarity protection: | ![]() |
| Short-circuit protection: | ![]() |
| Housing material: | Plastic |
| Power-up pulse suppression: | ![]() |
| Ambient temperature, operation: | -25 C ... 80 C |
| Shock/vibration stress: | 30 g, 11 ms/10 ... 55 Hz, 1 mm |
| Residual current: | ≤ 0.5 mA |
| Dimensions (W x H x D): | 80 mm x 40 mm x 105 mm |
| Sensing area material: | Plastic, PPE |
| Xxx: | M20 x 1.5 |
| Wire section: | ≤ 2.5 mm2 |
| 1) Without load 2) | |
Contact Us