SICK WL24-2X430 Overview
Reflex Photoelectric Switch WL24-2X430 Ex II 2G Es 1a op is IIC T4
SICK WL24-2X430 Description
- Classification: EX II 2G Ex ia op is IIC T4 according to Directive 94/9/EC (ATEX)
- Corresponds to Category 2G
- Output type: EN 60947-5-6 (NAMUR)
- Long sensing range
- Red light
- M12 or terminal chamber connection: 90 rotatable
- Durable metal housing
- Allows longer sensing range despite the limited factors of the norms for Category 2G (ATEX, explosive environments)
- Metal housing that has been IP 69K tested provides reliability and a long service life
- Flexible installation due to 90 rotatable connector
Your benefits
Features | |
Dimensions (W x H x D):: | 27 mm x 87.5 mm x 65 mm |
Sensing range max.: | 0 m ... 22 m 1) |
Sensing range: | 0 mm ... 15 mm 2) |
Housing desig (light emission): | Cuboid |
Light source: | LED 3) |
Type of light: | visible red light |
Sensitivity adjustment: | Sensitivity adjustment |
Sensor/detection principle: | Photoelectric retro-reflective sensor |
Light spot (distance): | 250 mm (15 m) |
1) 2) PL80A 3) Average service life 100,000 h at Ta = +25 C | |
Mechanics/electronics | |
Enclosure rating: | IP 67 |
Supply voltage: | 5 V DC ... 15.5 V DC 1) |
Residual ripple: | < 0.4 Vpp 2) |
Switching output: | NAMUR, light switching |
Response time: | ≤ 10 ms 3) |
Switching frequency: | 50 Hz 4) |
Connection type: | Connector M12, 4-pin 5) |
Protection class: | II 6) |
Circuit protection: | A C 7) 8) |
Weight: | 330 g |
Housing material: | Zinc diecast |
Optics material: | glass |
Ambient temperature, operation: | -20 C ... 60 C |
Ambient temperature, storage: | -25 C ... 70 C |
Polarisation filter: | ![]() |
Special device: | - |
Front screen heating: | - |
EC type approval certificate: | PTB 08 ATEX 2029 |
Ex marking (ATEX): | II 2G Ex ia op is IIC T4 according to directive 94/9/EG (ATEX) |
Hazardous area category: | 2G |
Input voltage Ui max: | 15.5 V 9) |
Input power Pimax.: | 100 mW 10) |
Input current Ii max: | 53 mA 11) |
Internal capacitance Ci max.: | 80 nF 12) |
Internalinductance Li max.: | 0 H 13) |
1) Limit values, supply with switching amplifier EN2Ex (internal resistor approx. 1 kOhm) 2) May not exceed or fall short of VS 3) Signal transit time with resistive load 4) With light/dark ratio 1:1 5) Connection rotable by 90 6) Reference voltage 50 V DC 7) A = VS connections reverse-polarity protected 8) C = interference suppression 9) 10) 11) 12) 13) For connection to a sperately certified intrinsically safe circuit only |