f SICK WL260-S270 (6020767)- A&S Automation Co., Ltd
 
Home / Sensors / Sick Sensor / SICK WL260-S270 (6020767)

Add To Cart
share


SICK WL260-S270 Overview



Reflex Photoelectric Switch WL260-S270

SICK WL260-S270 Description



  • Long sensing ranges
  • Mounting bracket and reflector included with delivery
  • Selectable operation mode (light/dark)
  • Optional time stages
  • M12 connector or terminal chamber
  • Versions for 10 - 30 V DC or 12 - 240 V DC/ 24 240 V AC voltage supply
  • Your benefits

  • High operating reserve provides increased reliability
  • Configuration controls are protected by a cover, ensuring less damage and a longer service life
  • Easily accessible terminal chamber for electrical connections simplifies installation
  • Simplified integration due to mounting compatibility since variants for DC or DC/AC voltage supply are available in the same design
  • Polarizing filter ensures reliable detection, even with shiny targets

Features
Dimensions (W x H x D)::25 mm x 78 mm x 63 mm
Sensing range max.: 0.01 m ... 15 m 1)
Sensing range: 0.01 m ... 10 m
0.01 m ... 13 m 2) 3)
Housing desig (light emission):Cuboid
Light source:LED 4)
Type of light:visible red light
Sensitivity adjustment:Potentiometer, 270
Sensor/detection principle:Photoelectric retro-reflective sensor
Light spot (distance):300 mm (10 m)
1) 3) PL80A 2) P250 4) Average service life 100,000 h at Ta = +25 C
Mechanics/electronics
Enclosure rating:IP 67
Supply voltage:12 V DC ... 240 V DC
24 V AC ... 240 V AC 1) 2)
Switching output:Relay, light switching, change-over contacts, electrically isolated 3)
Response time:≤ 20 ms
Switching frequency:25 Hz 4)
Connection type:Cable gland
Protection class:II 5)
Circuit protection:A
C

6) 7)
Weight:120 g
Housing material:ABS
Optics material:PMMA
Ambient temperature, operation:-25 C ... 55 C
Ambient temperature, storage:-40 C ... 70 C
Polarisation filter:
Items supplied:mounting bracket BEF-W260, Reflector P250
Special device:-
Angle of dispersion:1.7
Power consumption:≤ 5 VA
Switching current (switching voltage):3 A (240 V AC)
3 A (30 V DC)
Usage category:AC-15, DC-13, according to EN 60947-1
Interference emission:"residential and commercial areas", Level EN 61000-6-3
1) 2) +-10 % 3) Provide suitable spark supression for inductive or capacitive loads 4) With light/dark ratio 1:1 5) Rated voltage 250 V AC/DC 6) A = VS connections reverse-polarity protected 7) C = interference suppression