WL27X-3P1831 Photoelectric reflex switch
SICK WL27X-3P1831 Description
- Marking: EX II 3D IP67 T70C, EX II 3G EEx nA II T4 X according to Directive 94/9/EC (ATEX)
- Corresponds to 3D/3G category
- Conform with standards and ready-to-install: Sensor + protective housing (stainless steel 1.4301)
- High scanning range, high operating reserves
- Red
- Reliable operation in industrial environments and when devices are mounted opposite one another
- Ready-to-install sensors conform with the 3G/3D category for explosive zones (ATEX)
- Less downtime plus resistance to contamination due to high operating reserves
- Extremely vibration resistant and therefore largely independent of ambient conditions
- Wide range of applications with respect to operating temperature: -40 C - +60 C
Your benefits
Features | |
Dimensions (W x H x D):: | 31.4 mm x 112.3 mm x 70.4 mm |
Sensing range max.: | 0.1 m ... 15 m 1) |
Sensing range: | 0.1 m ... 11 m 2) |
Light source: | LED 3) |
Type of light: | visible red light |
Wave length: | 660 nm |
Light spot diameter (distance): | 220 mm (10 m) |
Adjustment: | adjustable |
Sensitivity adjustment: | Adjustable Potentiometer |
1) 2) PL80A 3) Average service life 100,000 h at Ta = +25 C | |
Mechanics/electronics | |
Enclosure rating: | IP 67 |
Supply voltage: | 10 V DC ... 30 V DC 1) |
Residual ripple: | ≤ 5 Vpp 2) |
Power consumption: | ≤ 30 mA 3) |
Switching output: | PNP, light/dark-switching, Complementary |
Output current Imax.: | ≤ 100 mA |
Response time: | ≤ 500 s 4) |
Switching frequency: | 1,000 Hz with light/dark ratio 1:1 |
Connection type: | Cable, 4-wire 10 m 5) |
Cable material: | PVC |
Number of cores: | 4 |
Protection class: | II 6) |
Circuit protection: | A B C 7) 8) 9) |
Weight: | 750 g |
Housing material: | ABS, Stainless steel 1.4301 |
Optics material: | PMMA |
Ambient temperature, operation: | -20 C ... 50 C |
Ambient temperature, storage: | -40 C ... 75 C |
Polarisation filter: | ![]() |
Signal voltage PNP HIGH / LOW: | approx. VS - 2.5 V / 0 V |
Angle of dispersion: | 1.5 |
Ex marking (ATEX): | EX II 3D IP67 T70 C Ex II 3G EEx nA II T4 X |
Hazardous area category: | 3D, 3G |
1) Limit values, operation in short-circuit protected network max. 8 A 2) May not exceed or fall short of VS 3) Without load 4) Signal transit time with resistive load 5) Do not bend below 0 C 6) Reference voltage 50 V DC 7) A = VS connections reverse-polarity protected 8) B = inputs and output reverse-polarity protected 9) C = interference suppression |