f SICK WL27-3S3731 (1027777)- A&S Automation Co., Ltd
 
Home / Sensors / Sick Sensor / SICK WL27-3S3731 (1027777)

Add To Cart
share


SICK WL27-3S3731 Overview



Photoelectric reflex switch WL27-3S3731 red light, relay, pigtail with rectangular plug, 7 pins

SICK WL27-3S3731 Description



  • High scanning range, high operating reserves
  • Faster alignment with red light
  • Reliable operation in industrial environments and when devices are mounted opposite one another
  • Front screen heating, time functions
  • Operating temperature: -40 C - +60 C
  • UL approval
  • Your benefits

  • Less downtime plus resistance to contamination due to high operating reserves
  • Flexible usage due to extended functionality e.g. time functions
  • Extremely vibration resistant and therefore largely independent of ambient conditions
  • For use at temperatures as low as 40 C
  • Highly stable housing due to offset fixing holes

Features
Dimensions (W x H x D)::24.6 mm x 80.6 mm x 54 mm
Sensing range max.: 0.1 m ... 15 m 1)
Sensing range: 0.1 m ... 11 m 2)
Light source:LED 3)
Type of light:visible red light
Wave length:660 nm
Light spot diameter (distance):220 mm (10 m)
Adjustment:adjustable
Sensitivity adjustment:Adjustable Potentiometer
1) 2) PL80A 3) Average service life 100,000 h at Ta = +25 C
Mechanics/electronics
Enclosure rating:IP 66
IP 67
Supply voltage:24 V AC/DC ... 240 V AC/DC 1)
Switching output:Relay, light switching, change-over contacts, electrically isolated 2)
Response time:≤ 10 ms
Switching frequency:10 Hz with light/dark ratio 1:1
Connection type:cable with plug Q7, 7-pin, AC/UC-coding 150 mm
Cable material:PVC
Number of cores:7
Protection class:

II

3)
Circuit protection:A
C
4) 5)
Weight:140 g
Housing material:ABS
Optics material:PMMA
Ambient temperature, operation:-40 C ... 60 C
Ambient temperature, storage:-40 C ... 75 C
Polarisation filter:
Angle of dispersion:1.5
Power consumption:≤ 2.5 VA
Switching current (switching voltage):3 (250)
3 (24)
0.11 (250)
Usage category:AC-15, DC-13, according to EN 60947-1
1) +- 10 % 2) Provide suitable spark supression for inductive or capacitive loads 3) Reference voltage 250 V AC 4) A = VS connections reverse-polarity protected 5) C = interference suppression


Hot Products
Reviews(0)
Write a Review

Level:
 
Name:  
Reviews: