Add To Cart
share
SICK WL34-V230 Overview
Reflex Photoelectric Switch WL34-V230 PNP/NPN, Light/Dark switching selector, Terminal chamber, Test input, Alarm
SICK WL34-V230 Description
- High operating reserve at a long range
- Switch selectable PNP or NPN output
- and light/dark switching
- Versions with DC voltage (10...30V) or universal AC/DC voltage (12 240 V DC / 24 240 V AC)
- Optional test input, adjustable ON and OFF time delays, alarm output
- M12 or terminal chamber connection: 90 rotatable
- UL approval
- High operating reserve at a long range minimizes downtime
- Alarm output provides early warning that maintenance may be needed
- Test input allows users to validate that the sensor is operating as expected
- The sensor cover protects configuration components against environmental hazards
- Adjustable time delay, alarm output, test input, and universal AC/DC voltage provide additional flexibility and reduce the number of part numbers needed
Your benefits
Features | |
Dimensions (W x H x D):: | 27 mm x 92 mm x 70 mm |
Sensing range max.: | 0.03 m ... 22 m 1) |
Sensing range: | 0.03 m ... 22 m 2) |
Housing desig (light emission): | Cuboid |
Light source: | LED 3) |
Type of light: | visible red light |
Wave length: | 660 nm |
Sensitivity adjustment: | Potentiometer |
Sensor/detection principle: | Photoelectric retro-reflective sensor |
Light spot (distance): | 250 mm (15 m) |
1) 2) PL80A 3) Average service life 100,000 h at Ta = +25 C | |
Mechanics/electronics | |
Enclosure rating: | IP 67 |
Supply voltage: | 10 V DC ... 30 V DC 1) |
Residual ripple: | < 5 Vpp 2) |
Power consumption: | ≤ 50 mA |
Switching output: | NPN, light switching, selectable via PNP/NPN selector PNP, Dark-switching, selectable via light/dark selector |
Output current Imax.: | 100 mA |
Response time: | ≤ 500 s 3) |
Switching frequency: | 1,000 Hz 4) |
Electrical connection: | Terminal connection with M16 gland 5) |
Protection class: | II 6) |
Circuit protection: | A C D 7) 8) 9) |
Weight: | 140 g |
Housing material: | ABS |
Ambient temperature, operation: | -40 C ... 60 C |
Ambient temperature, storage: | -40 C ... 75 C |
Test input sender off: | TE to 0 V |
Polarisation filter: | ![]() |
Special device: | - |
1) Limit values 2) May not exceed or fall short of VS 3) Signal transit time with resistive load 4) With light/dark ratio 1:1 5) Connection rotable by 90 6) Reference voltage 50 V DC 7) A = VS connections reverse-polarity protected 8) C = interference suppression 9) D = outputs overcurrent and short-circuit protected |