Add To Cart
share
Sick CSM1-N1114 Overview
Color Sensor CSM1-N1114 One ref. scanning distance 12,5 mm Plug 4 pin, M12 3 Tolerance modes
Sick CSM1-N1114 Description
- One color can be saved
- 12.5 mm sensing distance
- Switching frequency 1.5 kHz
- Color tolerance (precise, medium, coarse) can be set
- Static object teach-in via control cable or control panel
- Small housing
- Easy integration into existing machines - even in places where space is limited
- Fast and easy setup saves time and costs
- Broad spectrum of color tolerances enables more flexible use
Your benefits
Features | |
Dimensions (L x W x H): | 22 mm x 12 mm x 40 mm |
Sensing distance 1): | 12.5 mm |
Sensingdistance tolerance: | 2 mm |
Light source 2) 3): | LED red, green, blue |
Light spot size: | 1.5 mm x 6.5 mm |
Light spot direction: | Vertical |
Adjustment: | Static 1-point teach-in |
1) From front edge of lens 2) Average service life of 100,000 h at TA = +25 C 3) Wave length: 470 nm, 525 nm,640 nm | |
Mechanics/electronics | |
Supply voltage Vs: | DC 12 V ... 24 V |
Residual ripple 1): | < 5 Vpp |
Power consumption 2): | < 35 mA |
Switching frequency 3): | 1.5 kHz |
Response time 4): | 500 s |
Switching output: | NPN: HIGH = approx.VS/ LOW ≤ 2 V |
Switching output: | NPN |
Output (channel): | 1 color |
Output current Imax.: | < 100 mA |
Input, teach-in (ET): | NPN: Teach: U < 2 V Run: U= 10 V... < UV |
Connection type: | Connector M12, 4-pin |
Protection class 5): | II |
Circuit protection: | VS connections reverse-polarity protected Output Q short-circuit protected Interference suppression |
Enclosure rating: | IP 67 |
Weight: | ca. 11 g |
Housing material: | ABS |
1) May not exceed or fall short of VS tolerances 2) Without load 3) With light/dark ratio 1:1 4) Signal transit time with resistive load 5) Reference voltage 50 V DC Limit values: DC 12 V (-10 %) ... DC 24 V (+20 %). Operation in short-circuit protected network max. 8 A | |
Ambient data | |
Ambient temperature: | Operation: -10 ... 55 C Storage: -20 ... 75 C |
Shock load: | according to IEC 60068 |