Add To Cart
share
Sick DME5000-311S09 Overview
DISTANCE MEASURING DEVICE
Sick DME5000-311S09 Description
- Measurement range from 0.15 m to 300 m
- Highest output rate
- Highest accuracy, repeatability and system availability
- Illuminated LC display with diagnostic information
- Visible red light and bracket with springs for alignment
- Variety of interfaces: SSI, RS-422, PROFIBUS, HIPERFACE, DeviceNet
- Fastest measurement rate offers optimized integration into control loops for increased productivity
- Red laser light as well as adjustable mounting brackets (optional accessory) enable fast and easy alignment, ensuring on-time and cost-effective installation
- Multi-point self checks provide maintenance and replacement warnings increasing overall machine availability
- A tough, metal housing as well as heating and cooling accessories ensure reliability in rough ambient conditions
- User-friendly display with easy-to-use menu along with external PC/PLC programming offers fast and cost-efficient setup
- Multiple serial interfaces provide high-speed position output to the controller and high flexibility in application integration
- Integrated speed monitoring offers additional information for increased process reliability
- Highest degree of accuracy and repeatability ensures high machine availability
Your benefits
Performance | |
Measuring range (on diamond grade): | 0.15 m ... 300 m |
Resolution (adjustable): | 0.05 mm ... 5 mm |
Repeatability 1): | 2 mm |
Accuracy: | 5 mm |
Output rate: | 1 ms |
Light source 2): | Laser diode, red light |
Laser protection class: | 2 (EN60825-1 / CDRH) |
Typ. light spot size (distance): | ≤ 550 mm (at 300 m) |
Note: | with special frequency F1 for parallel mounting |
Maximum speed: | 10 m/s |
1) Statistical error 1 ?, environmental conditions constant, min. warm-up time 10 min 2) Average service life of 50,000 h at TA = +25 C | |
Interfaces | |
Switching outputs (MF1/MF2): | B (push/pull) 1) |
Data interfaces: | SSI |
Output current Ia: | ≤ 100 mA |
Multi functional inputs 2) 3): | MF1 |
1) Hi>Vs-3 V / Lo<2 V 2) Hi>12 V / Lo<3 V 3) Not reverse polarity protected | |
Mechanics/electronics | |
Supply voltage Vs: | DC 18 V ... 30 V , Limit values |
Residual ripple 1): | < 5 Vpp |
Power consumption: | without heating at DC 24 V: < 250 mA |
Initialization time 2): | 1.5 |
Connection type: | M16, 8-pin |
Indication: | Display |
Typ. weightwithout cable: | ca. 1,650 g |
1) May not exceed or fall short of VS tolerances 2) After loss of reflector >200 ms at max. speed vmax <1 m/s Short circuit / overload protected Max. 100 nF/20 mH | |
Ambient data | |
Enclosure rating: | IP 65 |
Protection class: | II 1) |
EMC: | EN 61000-6-2, EN 55011 |
Ambient temperature: | Operation: -10 ... 55 C |
Effect of air pressure: | 0.3 ppm/hPa |
Effect of air temperature: | 1 ppm/K |
Temperature drift: | Typ. 0.1: |
Mechanical load: | Shock: >=EN 600 86-2-27 / -2-29 Sine: >=EN 600 68-2-6 Noise: >=EN 600 68-2-64 |
1) Reference voltage 32 V DC |