Sick DML40-2-1211 Overview
Distance measuring device DML40-2-1211 reflector, profibus
Sick DML40-2-1211 Description
- Measurement range from 0.5 m up to 1,200 m with a reflector
- Time-of-flight measurement
- Easy alignment thanks to pilot laser
- Freely programmable parameters
- RS-422, RS-232, PROFIBUS, analog and two switching outputs
- Near field blanking parameter for operation through a protection window
- Extremely long measurement ranges of up to 1,200 m on natural targets offer high flexibility in applications where range is key
- Special visible alignment laser allows fast and easy alignment - even over long distances, offering fast and cost- effective installation
- Tough, metal housing design for trouble-free operation in rough environmental conditions
- Class 1 IR laser for discrete and safe measurement and detection
- User-friendly software with an easy-to-follow interface ensures fast and cost optimized setup
- Serial and analog interfaces as well as two digital switching outputs offer local over/under limit and service signals
Your benefits
Performance | |
Measuring range (on diamond grade): | 600 ... 0.5 |
Measuring range (on reflector PL880FS01): | 0.5 m ... 800 m |
Measuring range (on reflector OP60): | 0.5 m ... 1,200 m |
Measurement cycle: | 5,120 values per second |
Average depth: | 1/16/64/256/1,024 |
Output rate: | 1 ms / 600 ms 1) |
Light source: | Laser diode, infrared |
Wave length: | 905 nm |
Laser protection class: | 1 (EN 60825-1:Nov.2001, IEC 60825-1:M2:2001) |
Typ. light spot size (distance): | Typ. 20 mm (+ (5x distance in m)) |
Response time: | 1 ms / 600 ms 2) |
Resolution 6 % ... 90 %: | 1 3) |
Repeatability 6 % ... 90% remission: | 6 mm 4) |
Accuracy 6 % ... 90 % remission: | 10 mm 5) 6) |
1) 3) 4) 5) 6) 2) Dependant on average setting, average depth, timeout, baud rate, data output, output format and effective dead time of aperture | |
Interfaces | |
Data interfaces: | PROFIBUS DP |
Data transmission rate: | 12 MBaud |
Interface for parametrization: | RS-232 |
Output current Ia: | 100 mA |
Mechanics/electronics | |
Supply voltage Vs: | DC 18 V ... 30 V , Limit values |
Residual ripple 1): | 5 Vpp |
Power consumption: | ≤ 6 W 2) |
Initialization time: | 6 |
Connection type: | Cable gland Sub D 9-pin |
Typ. weightwithout cable: | ca. 1,200 g |
1) 2) | |
Ambient data | |
Enclosure rating: | IP 65 |
Protection class: | III 1) |
EMC: | EN55011:1998 Kl. B, Gr.1, EN6100-6-2:1999 |
Ambient temperature: | Operation: -10 ... 55 C Storage: -25 ... 70 C |
Temperature drift: | Typ. 0.6: Typ. 0.3: 2) 3) |
Mechanical load: | Shock: >=IEC 60068-2-27, -2-29 Sine: >=IEC 60068-2-6 |
1) 2) -10 C ... 0 C, +40 C +55 C 3) 0 C ... +40 C |