Add To Cart
share
Sick DMP2-N21111S01 Overview
XY-Positionsfinder DMP2-N21111S01 NPN, 5 switching outputs, doubled dimensions of capture range
Sick DMP2-N21111S01 Description
- Distances between 200 mm and 2,000 mm
- Switching and analog outputs available
- Analog output 4 mA ... 20 mA
- Easy alignment
- 90 rotatable plug
- 0.15 mm repeatability
- Field of view 10 in each direction
- Relative positioning on a reflector
- Increased productivity due to automated storage and retrieval processes
- Highest reliability in storage and retrieval applications due to relative positioning, which automatically compensates for mechanical rack deviations
- Increased positioning accuracy - relative positioning eliminates temperature-dependant deviations
- Improved process quality and positioning accuracy - sensor compensates for travel inconsistencies in storage and retrieval units
- Fast commissioning and setup due to easy teach-in procedure
Your benefits
Performance | |
Scanning distance on reflector PL22: | 200 mm ... 500 mm |
Scanning distance on reflector PL50A: | 500 mm ... 1,200 mm |
Scanning distance on reflector PL80A: | 500 mm ... 2,000 mm |
Repeatability: | 0.15 mm 1) |
Response time: | 3 ms |
Switching frequency: | 250 Hz |
Light source: | LED, red |
Scanning angle: | 10 2) |
Operating mode: | Choice of permanent or synchronised |
Note: | Fangbereich doppelte Gre |
1) At 300 mm scanning distance 2) In all axis vertical to the reflector (PL22, PL50A, PL80A) | |
Interfaces | |
Switching outputs: | 5 x NPN 1) |
Blanking input AT: | Blanked (triggered): NPN: 0V ... Uv - (≥ 18 V) Free running: NPN: Uv- (≤ 2 V) or free running |
Output current Ia: | 100 mA |
1) NPN: HIGH = VS, LOW ? 2 V | |
Mechanics/electronics | |
Supply voltage Vs: | DC 18 V ... 30 V |
Residual ripple: | < 5 Vpp 1) |
Power consumption: | Without load: < 250 mA |
Typ. weightwithout cable: | 990 g |
Connection type: | M12, 8-pin |
1) May notfall or exceed short of VS tolerances Limit values, reverse polarity protected | |
Ambient data | |
Enclosure rating: | IP 67 |
Protection class: | II 1) |
Ambient temperature: | Operation: -25 ... 55 C Storage: -25 ... 75 C |
Vibration resistance: | Nach IEC 68 |
1) Reference voltage 50 V DC |