Distance measuring device DMT10-2-1111
Sick DMT10-2-1111 Description
- Measurement range from 0.5 m up to 155 m on natural targets
- Excellent accuracy thanks to time-of-flight measurement
- Easy alignment thanks to pilot laser
- Freely programmable parameters
- RS-422, RS-232, PROFIBUS, analog and two switching outputs
- Near field blanking parameter for operation through a protection window
- Models with filter for measurement of glowing, hot metal (up to 1,400 C)
- Extremely wide measurement range of up to 155 m on natural targets offers high flexibility in applications where range is key
- Supplementary visible alignment laser allows fast and easy alignment - even over long distances, offering fast and cost- effective installation
- Tough, metal housing design for trouble-free operation in the roughest environmental conditions
- Non-visible, Class 1 IR laser for safe measurement and detection
- User-friendly software with an easy-to-follow interface ensures fast and cost- optimized setup
- Serial and analog interfaces as well as two digital switching outputs, allow flexible use for varied applications
- Integrated filter option allows for direct measurement of 1,200 C glowing, hot targets
Your benefits
Performance | |
Measurement cycle: | 1,024 values per second |
Average depth: | 1/16/64/256/1,024 |
Output rate: | 1 ms / 3,000 ms 1) |
Effective dead time of aperture: | ≤ 1 s 2) |
Light source: | Laser diode, infrared |
Wave length: | 905 nm |
Laser protection class: | 1 (EN 60825-1:Nov.2001, IEC 60825-1:M2:2001) |
Typ. light spot size (distance): | Typ. 20 mm (+ (5x distance in m)) |
Note: | mechanical aperture |
Measuring range 90 % remision: | 0.5 ... 155 m |
Measuring range 6 % remission: | 0.5 ... 40 m |
Response time: | 1 ms / 4,000 ms 3) |
Measuring range 18 % remission: | 0.5 ... 65 m |
Repeatability 90 % remission: | 10 mm 4) |
Repeatability 18 % remission: | 10 mm at 65 m distance |
Repeatability 6 % remission: | 10 mm at 40 m distance |
Resolution 6 % ... 90 %: | 1 5) |
Repeatability 6 % ... 90% remission: | 7 mm 10 mm 6) |
Accuracy 6 % ... 90 % remission: | 10 mm 7) 8) |
1) 2) 4) 5) 6) 7) 8) 3) Dependant on average setting, average depth, timeout, baud rate, data output, output format and effective dead time of aperture | |
Interfaces | |
Analog current outputs (max. load): | 4 ... 20 mA, scalable |
Data interfaces: | RS-232, RS-422 |
Output current Ia: | 100 mA |
Switching outputs (max. output current): | Q1, Q2, Qa 1) |
1) | |
Mechanics/electronics | |
Supply voltage Vs: | DC 18 V ... 30 V , Limit values |
Residual ripple 1): | < 5 Vpp |
Power consumption: | ≤ 6 W 2) |
Initialization time: | 6 |
Connection type: | Cable gland Sub D 9-pin |
Typ. weightwithout cable: | ca. 1,200 g |
1) 2) | |
Ambient data | |
Enclosure rating: | IP 65 |
Protection class: | III 1) |
EMC: | EN55011:1998 Kl. B, Gr.1, EN6100-6-2:1999 |
Ambient temperature: | Operation: -10 ... 55 C Storage: -25 ... 70 C |
Temperature drift: | Typ. 0.6: Typ. 0.3: 2) 3) |
Mechanical load: | Shock: >=IEC 60068-2-27, -2-29 Sine: >=IEC 60068-2-6 |
1) 2) -10 C ... 0 C, +40 C +55 C 3) 0 C ... +40 C |