Sick DMT10-2-2111 Overview



Distance measuring device DMT10-2-2111

Sick DMT10-2-2111 Description



  • Measurement range from 0.5 m up to 155 m on natural targets
  • Excellent accuracy thanks to time-of-flight measurement
  • Easy alignment thanks to pilot laser
  • Freely programmable parameters
  • RS-422, RS-232, PROFIBUS, analog and two switching outputs
  • Near field blanking parameter for operation through a protection window
  • Models with filter for measurement of glowing, hot metal (up to 1,400 C)
  • Your benefits

  • Extremely wide measurement range of up to 155 m on natural targets offers high flexibility in applications where range is key
  • Supplementary visible alignment laser allows fast and easy alignment - even over long distances, offering fast and cost- effective installation
  • Tough, metal housing design for trouble-free operation in the roughest environmental conditions
  • Non-visible, Class 1 IR laser for safe measurement and detection
  • User-friendly software with an easy-to-follow interface ensures fast and cost- optimized setup
  • Serial and analog interfaces as well as two digital switching outputs, allow flexible use for varied applications
  • Integrated filter option allows for direct measurement of 1,200 C glowing, hot targets

Performance
Measurement cycle:1,024 values per second
Average depth:1/16/64/256/1,024
Output rate:1 ms / 3,000 ms 1)
Effective dead time of aperture:1 ms 2)
Light source:Laser diode, infrared
Wave length:905 nm
Laser protection class:1 (EN 60825-1:Nov.2001, IEC 60825-1:M2:2001)
Typ. light spot size (distance):Typ. 20 mm (+ (5x distance in m))
Note:electronic aperture
Measuring range 90 % remision:0.5 ... 155 m
Measuring range 6 % remission:0.5 ... 40 m
Response time:1 ms / 3,000 ms 3)
Measuring range 18 % remission:0.5 ... 65 m
Repeatability 90 % remission:10 mm 4)
Repeatability 18 % remission:10 mm at 65 m distance
Repeatability 6 % remission:10 mm at 40 m distance
Resolution 6 % ... 90 %:1 5)
Repeatability 6 % ... 90% remission:7 mm 10 mm 6)
Accuracy 6 % ... 90 % remission: 10 mm 7) 8)
1) 2) 4) 5) 6) 7) 8) 3) Dependant on average setting, average depth, timeout, baud rate, data output, output format and effective dead time of aperture
Interfaces
Analog current outputs (max. load):4 ... 20 mA, scalable
Data interfaces:RS-232, RS-422
Output current Ia:100 mA
Switching outputs (max. output current):Q1, Q2, Qa 1)
1)
Mechanics/electronics
Supply voltage Vs:DC 18 V ... 30 V , Limit values
Residual ripple 1):< 5 Vpp
Power consumption:≤ 6 W 2)
Initialization time:6
Connection type:Cable gland Sub D 9-pin
Typ. weightwithout cable:ca. 1,200 g
1) 2)
Ambient data
Enclosure rating:IP 65
Protection class:III 1)
EMC:EN55011:1998 Kl. B, Gr.1, EN6100-6-2:1999
Ambient temperature:Operation: -10 ... 55 C
Storage: -25 ... 70 C
Temperature drift:Typ. 0.6:
Typ. 0.3:
2) 3)
Mechanical load:Shock: >=IEC 60068-2-27, -2-29
Sine: >=IEC 60068-2-6
1) 2) -10 C ... 0 C, +40 C +55 C 3) 0 C ... +40 C