Add To Cart
share
Sick DS500-N611 Overview
Distanz Sensor DS500-N611 2x NPN outputs, heating, range max. 70m
Sick DS500-N611 Description
- Measurement range 0.2 ... 70 m
- Two switching outputs
- Highest measurement resolution, repeatability and accuracy without a reflector
- Simple adjustment using red laser light
- Metal housing with integrated heating option for cold store applications
- Weather protection housing optional
- Alignment bracket optional
- High-precision switching reliably indicates product position for exact machine control, reducing scrap and increasing throughput
- Red laser light as well as adjustable mounting brackets (optional accessory) enable fast and easy alignment, ensuring on-time and cost-effective installation
- A tough, metal housing with internal heating ensures reliability in rough ambient conditions, such as cold store warehouses
- User-friendly display with easy-to-use menu along with external PC/PLC programming offers fast and cost-efficient setup
- Two individual programmable switching outputs offer flexible integration into application
- Wide measurement range of 0.2 m to 70 m enables automated measurement on natural targets where reflectors cant be used
Your benefits
Performance | |
Resolution 6 ... 90 %: | 1 |
Light source 1): | Laser diode, red light |
Laser protection class: | 2 (EN 60825/21 CFR 1.040) |
Typ. light spot size (distance): | 100 mm (at 70 m) |
Measuring range 90 % remision: | 0.2 ... 70 m |
Measuring range 6 % remission: | 0.2 ... 30 m |
Accuracy 6 ... 90 % remission: | 3 mm |
Response time: | 0.15 s / 6 s |
1) Average service life of 50,000 h at TA = +25 C | |
Interfaces | |
Switching hysteresis: | 6 |
Multi functional inputs 1): | < 2 V |
Switching outputs (max. output current): | NPN (<100 mA) 2) |
1) Refer to charts 2) PNP: Hi=Uv-2.5 V / Lo=0 V, NPN: Hi=Uv / Lo<2.5 V | |
Mechanics/electronics | |
Supply voltage Vs: | DC 10 V ... 30 V , Reverse polarity protected Us ≥ DC 24 V for devices with heating |
Residual ripple 1): | 5 Vpp |
Power consumption: | Typ. 22 W |
Initialization time: | 500 s |
Connection type: | M12, 5-pin |
Typ. weightwithout cable: | 1,000 g |
1) May notfall or exceed short of VS tolerances | |
Ambient data | |
Enclosure rating: | IP 65 |
Protection class: | II 1) |
EMC: | EN 60947-5-7: 2003-9, EN 61000-6-2, EN 55011 |
Ambient temperature: | Operation: -40 ... 50 C Storage: -25 ... 75 C |
Temperature drift: | Typ. 0.05: |
Mechanical load: | Shock: >=EN 600 86-2-27 Sine: >=EN 600 68-2-6 Noise: >=EN 600 68-2-64 |
1) Reference voltage 32 V DC |