f Sick DT2-410 (1024093)- A&S Automation Co., Ltd
 
Home / Sensors / Sick Sensor / Sick DT2-410 (1024093)

Add To Cart
share


Sick DT2-410 Overview



Photoelectric Proximity Switch DT2-410 with analog output

Sick DT2-410 Description



  • Measuring range of 50 mm ... 300 mm
  • Resolution of 1 mm
  • Infrared sender, which is not visible to the human eye
  • Analog output for use in measurement applications
  • Plug and play sensor - no adjustment necessary
  • Rugged and small metal housing
  • Your benefits

  • Plug and play -fast and easy commissioning without sensor adjustments
  • Inconspicuous and therefore non distracting by use of infrared light
  • Tough metal housing permits operation in harsh environments
  • Compact sensor housing makes it an ideal solution for applications with limited space
  • Analog output allows one sensor to solve several applications, reducing purchasing and engineering costs

Performance
Light source:LED, infrared
Typ. light spot size (distance):80 mm x 80 mm (at 300 mm)
Additional features:Plug & Play
Response time:200 ms
Measuring range 90 % remision:50 ... 300 mm 1)
Measuring range 6 % remission:50 ... 250 mm
Repeatability 90 % remission:1.5 mm ... 6 mm
10 mm ... 15 mm 2)
Accuracy 90 % remission: 3 mm ... 24 mm
Resolution 6 % ... 90 %:≤ 1 mm
1) Falling below of the measurement range results in ambiguous values, exceeding the measurement range results in values = 20.3 mA 2) Depending on current distance: ? 200 mm / > 200 mm
Interfaces
Analog current outputs (max. load):1x 4 mA... 20 mA
Mechanics/electronics
Supply voltage Vs:DC 18 V ... 30 V
Power consumption:≤ 3 W 1)
Housing material:Metal
Connection type:Connector M12, 4-pin
Residual ripple:≤ 5 Vpp 2)
1) Without load 2) May notfall or exceed short of VS tolerances Limit values, reverse-polarity protected, operation in short circuit protected network, max. 8 A
Ambient data
Enclosure rating:IP 67
Ambient temperature:Operation: -10 ... 45 C
Storage: -25 ... 75 C
Vibration resistance:EN 60068-2-6 / -2-64
Protection class:III 1)
Shock resistance:EN 60068-2-27 / -2-29
Average service life laser (MTTF at 25 C):100,000 h
1) Reference voltage 32 V DC