Sick DT2-410 Overview
Photoelectric Proximity Switch DT2-410 with analog output
Sick DT2-410 Description
- Measuring range of 50 mm ... 300 mm
- Resolution of 1 mm
- Infrared sender, which is not visible to the human eye
- Analog output for use in measurement applications
- Plug and play sensor - no adjustment necessary
- Rugged and small metal housing
- Plug and play -fast and easy commissioning without sensor adjustments
- Inconspicuous and therefore non distracting by use of infrared light
- Tough metal housing permits operation in harsh environments
- Compact sensor housing makes it an ideal solution for applications with limited space
- Analog output allows one sensor to solve several applications, reducing purchasing and engineering costs
Your benefits
Performance | |
Light source: | LED, infrared |
Typ. light spot size (distance): | 80 mm x 80 mm (at 300 mm) |
Additional features: | Plug & Play |
Response time: | 200 ms |
Measuring range 90 % remision: | 50 ... 300 mm 1) |
Measuring range 6 % remission: | 50 ... 250 mm |
Repeatability 90 % remission: | 1.5 mm ... 6 mm 10 mm ... 15 mm 2) |
Accuracy 90 % remission: | 3 mm ... 24 mm |
Resolution 6 % ... 90 %: | ≤ 1 mm |
1) Falling below of the measurement range results in ambiguous values, exceeding the measurement range results in values = 20.3 mA 2) Depending on current distance: ? 200 mm / > 200 mm | |
Interfaces | |
Analog current outputs (max. load): | 1x 4 mA... 20 mA |
Mechanics/electronics | |
Supply voltage Vs: | DC 18 V ... 30 V |
Power consumption: | ≤ 3 W 1) |
Housing material: | Metal |
Connection type: | Connector M12, 4-pin |
Residual ripple: | ≤ 5 Vpp 2) |
1) Without load 2) May notfall or exceed short of VS tolerances Limit values, reverse-polarity protected, operation in short circuit protected network, max. 8 A | |
Ambient data | |
Enclosure rating: | IP 67 |
Ambient temperature: | Operation: -10 ... 45 C Storage: -25 ... 75 C |
Vibration resistance: | EN 60068-2-6 / -2-64 |
Protection class: | III 1) |
Shock resistance: | EN 60068-2-27 / -2-29 |
Average service life laser (MTTF at 25 C): | 100,000 h |
1) Reference voltage 32 V DC |