Add To Cart
share
Sick DT500-A111 Overview
Distance Sensor DT500-A111 Analog output 20mA
Sick DT500-A111 Description
- Measurement range 0.2 ... 70 m
- One analog output, RS-422 or CAN
- Highest measurement resolution, repeatability and accuracy without a reflector
- Simple adjustment using red laser light
- Metal housing with integrated heating option for cold store applications
- Weather protection housing optional
- Alignment bracket optional
- High-precision measurement reliably indicates product position for exact machine control, reducing scrap and increasing throughput
- Red laser light as well as adjustable mounting brackets (optional accessory) enable fast and easy alignment, ensuring on-time and cost-effective installation
- A tough, metal housing with internal heating ensures reliability in rough ambient conditions, such as cold store warehouses
- User-friendly display with easy-to-use menu along with external PC/PLC programming offers fast and cost-efficient setup
- Serial interfaces or an analog output offer flexible integration into application
- Wide measurement range of 0.2 m to 70 m enables automated measurement on natural targets where reflectors cant be used
Your benefits
Performance | |
Output rate: | 250 ms |
Light source 1): | Laser diode, red light |
Laser protection class: | 2 (EN 60825/21 CFR 1.040) |
Typ. light spot size (distance): | 45 mm (at 30 m) |
Measuring range 90 % remision: | 0.2 ... 30 m |
Measuring range 6 % remission: | 0.2 ... 18 m |
Repeatability 6 ... 90% remission: | 1 mm 2) |
Accuracy 6 ... 90 % remission: | 3 mm |
1) Average service life of 50,000 h at TA = +25 C 2) Statistical error 1 ? | |
Interfaces | |
Analog current outputs (max. load): | 0 ... 20 mA/4 20 mA (Uv-2 V/0,0205 A) |
Resolution analog outputs: | 12 bit |
Multi functional inputs 1): | >12 V |
1) Refer to charts | |
Mechanics/electronics | |
Supply voltage Vs: | DC 10 V ... 30 V , Reverse polarity protected Us ≥ DC 24 V for devices with heating |
Residual ripple 1): | 5 Vpp |
Power consumption: | Typ. 3 W |
Initialization time: | 500 s |
Connection type: | M12, 5-pin |
Typ. weightwithout cable: | 1,000 g |
1) May notfall or exceed short of VS tolerances | |
Ambient data | |
Enclosure rating: | IP 65 |
Protection class: | II 1) |
EMC: | EN 60947-5-7: 2003-9, EN 61000-6-2, EN 55011 |
Ambient temperature: | Operation: -10 ... 50 C Storage: -25 ... 75 C |
Temperature drift: | Typ. 0.05: |
Mechanical load: | Shock: >=EN 600 86-2-27 Sine: >=EN 600 68-2-6 Noise: >=EN 600 68-2-64 |
1) Reference voltage 32 V DC |