f Sick DT500-A611 (1040467)- A&S Automation Co., Ltd
 
Home / Sensors / Sick Sensor / Sick DT500-A611 (1040467)

Add To Cart
share


Sick DT500-A611 Overview



Distance sensor DT500-A611 analo output 20mA, heating range 70 m

Sick DT500-A611 Description



  • Measurement range 0.2 ... 70 m
  • One analog output, RS-422 or CAN
  • Highest measurement resolution, repeatability and accuracy without a reflector
  • Simple adjustment using red laser light
  • Metal housing with integrated heating option for cold store applications
  • Weather protection housing optional
  • Alignment bracket optional
  • Your benefits

  • High-precision measurement reliably indicates product position for exact machine control, reducing scrap and increasing throughput
  • Red laser light as well as adjustable mounting brackets (optional accessory) enable fast and easy alignment, ensuring on-time and cost-effective installation
  • A tough, metal housing with internal heating ensures reliability in rough ambient conditions, such as cold store warehouses
  • User-friendly display with easy-to-use menu along with external PC/PLC programming offers fast and cost-efficient setup
  • Serial interfaces or an analog output offer flexible integration into application
  • Wide measurement range of 0.2 m to 70 m enables automated measurement on natural targets where reflectors cant be used

Performance
Output rate:0.15 s / 6 s
Light source 1):Laser diode, red light
Laser protection class:2 (EN 60825/21 CFR 1.040)
Typ. light spot size (distance):100 mm (at 70 m)
Measuring range 90 % remision:0.2 ... 70 m
Measuring range 6 % remission:0.2 ... 30 m
Repeatability 6 ... 90% remission:1 mm 2)
Accuracy 6 ... 90 % remission: 3 mm
1) Average service life of 50,000 h at TA = +25 C 2) Statistical error 1 ?
Interfaces
Analog current outputs (max. load):0 ... 20 mA/4 20 mA (Uv-2 V/0,0205 A)
Resolution analog outputs:12 bit
Multi functional inputs 1):>12 V
1) Refer to charts
Mechanics/electronics
Supply voltage Vs:DC 10 V ... 30 V , Reverse polarity protected
Us ≥ DC 24 V for devices with heating
Residual ripple 1):5 Vpp
Power consumption:Typ. 22 W
Initialization time:500 s
Connection type:M12, 5-pin
Typ. weightwithout cable:1,000 g
1) May notfall or exceed short of VS tolerances
Ambient data
Enclosure rating:IP 65
Protection class:II 1)
EMC:EN 60947-5-7: 2003-9, EN 61000-6-2, EN 55011
Ambient temperature:Operation: -40 ... 50 C
Storage: -25 ... 75 C
Temperature drift:Typ. 0.05:
Mechanical load:Shock: >=EN 600 86-2-27 / -2-29
Sine: >=EN 600 68-2-6
Noise: >=EN 600 68-2-64
1) Reference voltage 32 V DC