Add To Cart
share
Sick DT50-P1123 Overview
Distance sensor DT50-P1123 Laser Class 1 Sensing range 200?10000 mm Analogue output 4?20 mA 1 switching output PNP, invertable
Sick DT50-P1123 Description
- HDDM technology provides the best reliability, immunity to ambient light and price/performance ratio
- Reliable measurement and detection up to 10 m
- Wide choice of models: 4 mA ... 20 mA or 0.V .. 10 V; PNP or NPN and laser Class 1 or 2
- High switching repeatability ( 2.5 mm)
- Display with intuitive operating concept
- Tough die-cast zinc metal housing
- Wide operating temperature range from -30 C to +65 C
- Wide measurement range allows easy and fast integration in any production environment
- Intuitive setup via display or remote teach reduces installation time and costs
- Widest temperature range allows for outdoor use without additional cooling or heating accessories
- Immune to any type of ambient light - allows for use in optically challenging environments
- Increased process stability is achieved thanks to the small black/white shift
- Metal housing withstands harsh environments, saving replacement costs
- Low investment costs and high performance guarantee quick return on investment
- Dx50 family is based on a common platform, which offers multiple performance levels, making it easy to accommodate future changes
Your benefits
Performance | |
Measuring range 90 % remision: | 200 ... 10,000 mm |
Measuring range 18 % remission: | 200 ... 5,000 mm |
Measuring range 6 % remission: | 200 ... 2,500 mm |
Accuracy 90 % remission: | 10 mm |
Response time: | 20 ms / 30 ms 1) |
Output rate: | 4 ms |
Light source: | Laser, red 2) |
Laser protection class: | 1 (EN 60 825-1) |
Typ. light spot size (distance): | 15 mm x 15 mm (10 m) |
Additional features: | Set moving averaging: fast/slow, Switching mode: Distance to object (DtO), Teach-in of analog output, Teach in of switching outputs, Scaling of analog outputs, Set levels of switching outputs, Set hysterisis, Switching output invertable, Multi functional input: laser off, external teach, inactive, Switch off display, Reset to factory default, Lock user interface, Invertable analog output |
Resolution 6 % ... 90 %: | 1 mm |
Repeatability 6 % ... 90% remission: | 5 mm 2.5 mm 3) 4) |
1) 4) Dependent on the set averaging: fast/slow 2) Wavelength: 658 nm, max. output: 80 mW, pulse length: 2.5 ns, pulse repetition rate: 1/240 3) Equivalent to 1 ? | |
Interfaces | |
Analog current outputs (max. load): | 1x 4 mA ... 20 mA (≤ 300 Ω) |
Resolution analog outputs: | 16 Bit |
Switching hysteresis: | 10 mm ... 1,000 mm |
Switching outputs (max. output current): | 1 x PNP (100 mA) 1) 2) |
Multi functional inputs: | 1 x PNP 3) 4) |
1) Output Q short-circuit protected 2) PNP: High = VS- (< 2.5 V); Low = 0 V 3) Response time ? 15ms 4) PNP: High = VS, Low = ? 2.5 V | |
Mechanics/electronics | |
Supply voltage Vs: | DC 10 V ... 30 V |
Residual ripple: | ≤ 5 Vpp 1) |
Power consumption: | ≤ 2.1 W 2) |
Initialization time: | ≤ 250 ms |
Warm up time: | ≤ 15 min |
Typ. weightwithout cable: | 200 g |
Housing material: | Die-cast zinc housing (ZNAL4CU1) Plastic front window |
Connection type: | Connector M12, 5-pin |
Indication: | 2 x LED, LC Display |
1) May notfall or exceed short of VS tolerances 2) Without load Limit values, reverse-polarity protected, operation in short circuit protected network, max. 8 A | |
Ambient data | |
Enclosure rating: | IP 65 |
Protection class: | III |
Ambient temperature: | Operation: -30 ... 65 C Storage: -40 ... 75 C |
Max. rel. humidity (not condensing): | ≤ 95 % |
Typ. temperature drift: | 0.7 mm/K |
Vibration resistance: | EN 60068-2-6 / -2-64 |
Shock resistance: | EN 60068-2-27 / -2-29 |
Average service life laser (MTTF at 25 C): | 100,000 h |