Add To Cart
share
Sick ISD280-1112 Overview
ISD280-1112 Infrared system for data transfer, duplex mode, RS 422/485 operating voltage 24V DC carrier frequency 2
Sick ISD280-1112 Description
- Duplex operation
- RS-422 /485
- Profibus
- Interbus-S
- SSI Interface
| Features | |
| Comment: | A pair of devices with numbers ending in 1 and 2 are required to create a data transfer section. |
| Performance | |
| Scanning range: | 0.2 m ... 150 m |
| Light source: | Infrared LED (860 nm) |
| Typ. light spot size (distance): | ca. 1.4 m (at 100 m) |
| Field of view: | ca. 0.4 |
| Heating: | - |
| Interfaces | |
| Switching output: | VS - 2 V: interference-free operation, Iout = 20 mA |
| Switching input: | VS: sender deactivated |
| Data interfaces: | RS-422/-485 PROFIBUS DP |
| Data transmission rate: | 1.5 MBaud |
| Signal delay: | <= 2 s |
| Mechanics/electronics | |
| Supply voltage Vs: | DC 24 V, +20% / -5% (with heating) DC 24 V, 20 % (without heating) |
| Power consumption: | Without heating: ≤ 0.4 A With heating: ≤ 2.5 A |
| Typ. weight excl. accessories: | 1 kg |
| Housing material: | Metal |
| Connection type: | Socket Connector Sub-D, 9-pin M12, 5-pin |
| Ambient data | |
| Enclosure rating: | IP 54 |
| VDE protection class: | III |
| EMC: | EN 61000-6-2 EN 61000-6-4 |
| Ambient temperature: | Operation without heating: 0 ... 55 C Operation with heating: -38 ... 55 C Storage area: -20 ... 70 C 1) |
| Max. rel. humidity (not condensing): | 90 % |
| 1) Only for 0.5 MBd, +40 C for 1.5 MBd. | |
Contact Us
Hot Products