f Sick LFH-EBX25G1AS10SZ0 (6045009)- A&S Automation Co., Ltd
 
Home / Sensors / Sick Sensor / Sick LFH-EBX25G1AS10SZ0 (6045009)

Add To Cart
share






Sick LFH-EBX25G1AS10SZ0 Description



  • Cable length up to 100m
  • Available with PUR or FEP cable
  • Measuring ranges from 0...0.1 bar up to 025 bar
  • Measurement accuracy ≤0.25 % of span
  • Output signal 420 mA, 05 V or 010 V
  • Hermetically sealed stainless steel housing with protection cap (PA), stainless steel membrane
  • Temperature measurement (Pt100) optional
  • Optional surge protection
  • Your benefits

  • Precise level measurement even under difficult conditions where other measurement technologies fail
  • Well suited even for shallow levels
  • Rugged and reliable through robust mechanical design and high-grade materials
  • Very good reliability of operation through optional surge protection
  • An optional temperature measurement enables use with varying liquid temperatures
  • High resistance due to optional FEP cable
  • For cleaning purposes the probe can easily be taken out of the liquid
  • No openings required in the wall of the vessel

Features
Pressure type:Gauge pressure
Measurement range: 0 bar ... 0.25 bar
Process temperature: -10 C ... 50 C
CE-conformity:
Performance
Accuracy:<= +/- 0.25 % (of span)
Non-linearity:≤ 0.2 % (of span (Best Fit Straight Line, BFSL) according to IEC 61298-2)
Long-term drift/one-year stability:≤ 0.2 % of span (at reference conditions)
Temperature coefficient in rated temperature range:Mean TC of span ≤ 0.2 % of span / 10 K, Mean TC of zero: ≤ 0.2 % of span / 10 K(< 0.4 % for pressure ranges ≤ 0.25 bar)
Rated temperature range:0 C ... 50 C
Non-repeatability:≤ 0.1 % of span
Mechanics/electronics
Wetted parts:Pressure connection/ diaphragm: Stainless steel, Housing: Stainless steel, Protection cap: PA
Enclosure rating:IP 68
Output signal:4...20 mA
Connection type:Cable PUR
Supply voltage:10 V DC ... 30 V DC
Electrical safety:Short-circuit protection: QA towards M, Protection class: III, Surge protection: According to EN 61000-4-5 (1.5 J) optional for enhanced varient, Reverse polarity protection: L+ towards M
Dielectric strength:500 V DC, NEC Class 02 power supply (low voltage and low current max. 100 VA even under fault conditions)
Protection class III:
Weight sensor:0.2 kg
Weight cable:0.08 kg/m
CE-conformity:EMC directive: 2004/108/EEC, EN 61326-2-3
Ambient data
Storage temperature: -30 C ... 80 C


Hot Products
Reviews(0)
Write a Review

Level:
 
Name:  
Reviews: