Add To Cart
share
Sick LFP1000-A4NMB Description
- No mechanical moving parts
- Manually cutable and exchangeable monoprobe with lengths from 200 mm up to 2,000 mm
- Immune to deposit formation
- Process temperature up to 100 C; process pressure up to 10 bar
- Small inactive areas, ideal for small containers
- Accurate measurement, even when liquid type changes
- 3-in-1: combined display, analog output (acc. NAMUR NE 43) and binary output
- High enclosure rating of IP 67, rotatable housing
- Rugged design increases service life
- High flexibility due to cutable and exchangable monoprobe
- Cost savings due to multiple output signals: one system for both level detection and continuous level monitoring
- Time and cost savings due to low maintenance and quick commissioning
- No calibration or recalibration required for commissioning, thus saving time and costs
- Compact and rotatable housing ensures flexible installation
- No crosstalk when several sensors are mounted next to each other
- Advanced technology enables adjustment-free measurement of oil- and water-based liquids
Your benefits
| Features | |
| Medium: | Fluids |
| Measurement: | switch, continuous |
| Probe length: | 1,000 mm |
| Process pressure: | -1 bar ... 10 bar |
| Process temperature: | -20 C ... 100 C |
| GOST approval: | ![]() |
| RoHS certificate: | ![]() |
| Performance | |
| Dielectricity constant: | ≥ 5 |
| Repeatability: | ≤ 2 mm |
| Resolution: | < 2 mm |
| Accuracy of sensor element: | 5 mm |
| Conductivity: | no limitation |
| Inactive area at process connector: | 25 mm 1) |
| Inactive area at probe end: | 10 mm 2) |
| Maximum level change: | 500 mm/s |
| 1) With parameterized tank with water under reference conditions, otherwise 40 mm 2) With water under reference conditions | |
| Mechanical data | |
| Housing material: | Plastic PBT |
| Process connection: | G 3/4 A |
| Wetted parts: | 1.4404, PTFE |
| Max.probe load: | 6 Nm |
| Electrical data | |
| Supply voltage: | 12 V DC ... 30 V DC 1) |
| Power consumption: | ≤ 75 mA at 24 V without output load |
| Initialization time: | ≤ 2 s |
| Hysteresis: | min. 2 mm, free adjustable |
| Connection type: | M12x1, 5-pin |
| Response time: | < 400 ms |
| Signal voltage HIGH: | Vs - 2 V |
| Signal voltage LOW: | ≤ 2 V |
| Output current: | < 100 mA |
| Output load: | 0 V ... 10 V > 750 Ohmat Uv >= 14 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 15 V |
| Upper signal level: | 20 mA ... 20.5 mA |
| Lower signal level: | 3.8 mA ... 4 mA |
| Capacitive load: | 100 nF |
| Inductive load: | < 1 H |
| Enclosure rating: | IP 67: EN 60529 |
| Temperature drift: | < 0.1 mm/K |
| Protection class: | III |
| EMC: | EN 61326-1:2006, 2004/108/EG |
| 1) All connections are polarity protected. All outputs are overload and short-circuit protected. | |
| Ambient data | |
| Ambient temperature, operation: | -20 C ... 60 C |
| Ambient temperature, storage: | -40 C ... 80 C |
Contact Us