Add To Cart
share
Sick PBT-CB1X6SGTSSNALA0Z Description
- Compound pressure measurement ranges from -1 ... 0 bar up to -1 +24 bar
- A large variety of available process connections
- No moving parts: No mechanical wear, fatigue-proof, maintenance-free
- Circularly welded, hermetically sealed stainless steel membrane
- Output signal 4 20 mA, 0 5 V or 0 10 V
- Electrical connection M12x1, L-connector acc. to DIN 175301-803 A or flying leads
- Compact size takes up less space
- Simple and cost-saving installation
- Available in a wide selection of configurations, enabling a perfect match to individual customer requirements
- Robust design enables higher reliability
- Excellent price/performance ratio
Your benefits
| Features | |
| Pressure type: | Compound pressure |
| Measurement range: | -1 bar ... 0.6 bar |
| Process temperature: | 0 C ... 80 C |
| CE-conformity: | ![]() |
| Performance | |
| Accuracy: | <= +/- 1 % (of span) |
| Non-linearity: | 0.5 % ((Best Fit Straight Line, BFSL) according to IEC 61298-2) |
| Response time: | < 4 ms |
| Long-term drift/one-year stability: | ≤ 0.1 % of span according to IEC 61298-2 |
| Rated temperature range: | 0 C ... 80 C |
| Service life: | 10 Mio. max. life cycles |
| Non-repeatability: | ≤ 0.1 % of span |
| Adjustment accuracy of zero signal: | <= 0.5 typ., 0.8 %max. %of span |
| Hysteresis: | 0.16 % 1) |
| Signal noise: | ≤ 0.3 % of span |
| 1) Of span | |
| Mechanics/electronics | |
| Process connection: | G 1/2 A according to DIN 3852-E |
| Wetted parts: | Pressure connection: 316L, Pressure sensor: 316L (for measurement ranges from 0 bar ... 10 bar rel: 13-8 PH) |
| Sealing: | NBR |
| Pressure port: | Standard |
| Housing material: | 316L |
| Enclosure rating: | IP 67 |
| Output signal: | 4...20 mA |
| Connection type: | L-connector acc. to DIN 175301-803 A, IP 65 |
| Supply voltage: | 8 V DC ... 35 V DC |
| Power consumption: | Max. 8 mA for voltage output signal, Signal current (max. 25 mA) for current output |
| Electrical safety: | Short-circuit protection: QA towards M, Reference conditions: According to IEC 61298-1, Protection class: III, Overvoltage protection: 32 V DC, 36 V DC with 4 mA ... 20 mA, Reverse polarity protection: L+ towards M |
| Protection class III: | ![]() |
| Weight sensor: | ca. 80 g |
| Isolation voltage: | 500 V DC 1) |
| CE-conformity: | Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EEC, EN 61326-2-3 |
| 1) The unit shall be supplied by a Limited Energy circuit in accordance to 9.3 of UL/EN/IEC 61010-1 or LPS in accordance to UL/EN/IEC 60950-1 or Class 2 in accordance to UL1310/UL1585 (NEC or CEC) and that the power supply shall be suitable for operation above 2,000 m, if the transmitter is used above this altitude. | |
| Ambient data | |
| Storage temperature: | 0 C ... 80 C |
| Ambient temperature: | 0 C ... 80 C |
| Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) |
| Vibration load: | 10 g according to IEC 60068-2-6 (vibration under resonance), 20 g optional |
| Relative humidity: | 45 % ... 75 % |
Contact Us