Add To Cart
share
Sick PBT-RK100SM2SSSAMA0Z Overview
PRESSURE SENSOR
Sick PBT-RK100SM2SSSAMA0Z Description
- Gauge pressure measurement ranges from 0 ... 1 kg/cm2 up to 0 600 kg/cm2
- A large variety of available process connections
- No moving parts: No mechanical wear, fatigue-proof, maintenance-free
- Circularly welded, hermetically sealed stainless steel membrane
- Output signal 4 20 mA, 0 5 V or 0 10 V
- Electrical connection M12x1, L-connector acc. to DIN 175301-803 A or flying leads
- Compact size takes up less space
- Simple and cost-saving installation
- Available in a wide selection of configurations, enabling a perfect match to individual customer requirements
- Robust design enables higher reliability
- Excellent price/performance ratio
Your benefits
Features | |
Pressure type: | Gauge pressure |
Measurement range: | 0 kg/cm2 ... 100 kg/cm2 |
Process temperature: | 0 C ... 80 C |
CE-conformity: | ![]() |
Performance | |
Accuracy: | <= +/- 1 % (of span) |
Non-linearity: | 0.5 % ((Best Fit Straight Line, BFSL) according to IEC 61298-2) |
Response time: | < 4 ms |
Long-term drift/one-year stability: | ≤ 0.1 % of span according to IEC 61298-2 |
Rated temperature range: | 0 C ... 80 C |
Service life: | 10 Mio. max. life cycles |
Non-repeatability: | ≤ 0.1 % of span |
Adjustment accuracy of zero signal: | <= 0.5 typ., 0.8 %max. %of span |
Hysteresis: | 0.16 % 1) |
Signal noise: | ≤ 0.3 % of span |
1) Of span | |
Mechanics/electronics | |
Process connection: | M20 x 1.5 |
Wetted parts: | Pressure connection: 316L, Pressure sensor: 316L (for measurement ranges from 0 bar ... 10 bar rel: 13-8 PH) |
Sealing: | Stainless steel |
Pressure port: | Standard |
Housing material: | 316L |
Enclosure rating: | IP 67 |
Output signal: | 4...20 mA |
Connection type: | M12 x 1, 4-pin, IP 67 |
Supply voltage: | 8 V DC ... 30 V DC |
Power consumption: | Max. 8 mA for voltage output signal, Signal current (max. 25 mA) for current output |
Electrical safety: | Short-circuit protection: QA towards M, Reference conditions: According to IEC 61298-1, Protection class: III, Overvoltage protection: 32 V DC, 36 V DC with 4 mA ... 20 mA, Reverse polarity protection: L+ towards M |
Protection class III: | ![]() |
Weight sensor: | ca. 80 g |
Isolation voltage: | 500 V DC 1) |
CE-conformity: | Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EEC, EN 61326-2-3 |
1) For power supply use a circuit with energy limitation (EN/UL/IEC 61010-1. section 9.3) with the following maximum values for the current: L+ = 30 V (DC): 5 A. Provide a separate switch for the external power supply. Alternative for North America: The connection may also be made to "Class 2 Circuits" or "Class 2. Power Units" according to CEC (Canadian Electrical Code) or NEC (National Electrical Code) | |
Ambient data | |
Storage temperature: | 0 C ... 80 C |
Ambient temperature: | 0 C ... 80 C |
Shock load: | 500 g according to IEC 60068-2-27 (mechanical shock) |
Vibration load: | 10 g according to IEC 60068-2-6 (vibration under resonance), 20 g optional |
Relative humidity: | 45 % ... 75 % |