Sick PLS101-312 Description



  • Protective field range 4 m
  • Freely programmable protective fields and warning fields

Applications
Hazardous area protection (vertical):-
Access protection (vertical):-
Hazardous area protection (horizontal):
Functions
Simultaneous monitoring of two areas:-
Static control outputs for switching between warning fields:-
Incremental encoder inputs:-
External device monitoring:-
Reflector mark detection:-
Expanded measured data output:-
Technical data
Laser protection class:1
Enclosure rating:IP 65 (EN 60529)
Protection class:2 (totally isolated)
Type:Type 3 (IEC/EN 61496-1)
Ambient operating temperature from ... to:0 C ... 50 C
Dimensions (W x H x D)::155 mm x 185 mm x 156 mm
Weight:4.5 kg
Maximum warning field range:50 m
Response time:> 80 ms
Resolution:< 70 mm
Distance measuring range:49 m
Number of multiple samplings:2 ... 16
Electrical connection:Plug-in connection box with cable fitting, Crimp contacts
Supply voltage:16.8 V DC, 24 V DC, 28.8 V DC
Number of reset-/restart inputs:1
Number of safe outputs:2, Safety outputs (OSSD)
Number of warning field outputs:1
Maximum output current:250 mA
Data interface:RS-232/RS-422