Sick UE4155 Overview



UE 4155 8 field-signal connections; 2 SDL connections; incl. CDS Software; suitable for function packages for CDS

Sick UE4155 Description



  • Remote module up to enclosure rating IP 67
  • Support for PROFIBUS-DP V1: cyclic communication with DP-Master Class 1 (central control), acyclic communication with DP-Master Class 2 (configuration and diagnostic tool)
  • Support for PROFIsafe V2.0
  • Two SDL connections for easy integration of intelligent SICK safety sensors
  • Simple configuration and diagnostics using the CDS (Configuration & Diagnostic Software)
  • Your benefits

  • Reduced implementation costs using safety automation devices without a control cabinet
  • Fast integration of safety solutions into a safety PLC, or into a wide PROFIBUS PROFIsafe fieldbus
  • Allows use of extended functionality of SICK safety sensors in an easy to use fashion
  • Comprehensive diagnostics provide fast troubleshooting, which reduces downtime

Applications
Safety command devices:
Electro-mechanical safety switches:
Non-contact safety switches:
Opto-electronic protective devices:
Two-hand control systems:
Operating mode selector switch:
Muting sensors:
Muting lamp:
Functions
Safedevice communication via EFI/SDL:
Reset/restart:Manual / automatic / configurable
Technical data
Fieldbus:PROFIBUS PROFIsafe
Enclosure rating:IP 67
Ambient operating temperature from ... to:0 C ... 55 C
Protection class:III
Weight:620 g
Safety integrity level:SIL3 (IEC 61508)
Category:Category 4 (EN ISO 13849)
Performance level:PL e (EN ISO 13849)
PFHd:1.33 * 1E-09
TM (Mission Time):20 a
Supply voltage:19.2 V DC, 24 V DC, 28.8 V DC
Maximum power consumption:≤ 9 A
Number of safety inputs:8 dual-channelor 16 single-channel
Input voltage HIGH field signal inputs:11 V, 24 V, 28.8 V
Input delay field signal inputs:Configurable 0 ... 90 ms
Number of test/signal outputs (with current monitoring):≤ 16 (2)
Number of SDL connections:2
Output voltage HIGH field signal outputs:UV, without load, switched-on
Output current field signal output:0 mA ... 700 mA
Minimum current for fault monitoring: 7 mA ... 40 mA, on field-signal connections 7 and 8 1)
Maximum current SDL connections:1.4 A
Maximum internal resistance SDL connections (power supply):0.3 Ω
Input voltage HIGH SDL connections (OSSD inputs):13 V, 24 V, 28.8 V
Maximum test puls rate SDL connections (OSSD inputs):500 Hz
Maximum test pulse width SDL connections (OSSD inputs):700 s
Baud rate PROFIBUS connection:9.6 kbit/s ... 12 Mbit/s
Address range PROFIBUS connection:3 ... 125
Ident numberPROFIBUS:071A hex