Add To Cart
share
Sick UE4155 Overview
UE 4155 8 field-signal connections; 2 SDL connections; incl. CDS Software; suitable for function packages for CDS
Sick UE4155 Description
- Remote module up to enclosure rating IP 67
- Support for PROFIBUS-DP V1: cyclic communication with DP-Master Class 1 (central control), acyclic communication with DP-Master Class 2 (configuration and diagnostic tool)
- Support for PROFIsafe V2.0
- Two SDL connections for easy integration of intelligent SICK safety sensors
- Simple configuration and diagnostics using the CDS (Configuration & Diagnostic Software)
- Reduced implementation costs using safety automation devices without a control cabinet
- Fast integration of safety solutions into a safety PLC, or into a wide PROFIBUS PROFIsafe fieldbus
- Allows use of extended functionality of SICK safety sensors in an easy to use fashion
- Comprehensive diagnostics provide fast troubleshooting, which reduces downtime
Your benefits
Applications | |
Safety command devices: | ![]() |
Electro-mechanical safety switches: | ![]() |
Non-contact safety switches: | ![]() |
Opto-electronic protective devices: | ![]() |
Two-hand control systems: | ![]() |
Operating mode selector switch: | ![]() |
Muting sensors: | ![]() |
Muting lamp: | ![]() |
Functions | |
Safedevice communication via EFI/SDL: | ![]() |
Reset/restart: | Manual / automatic / configurable |
Technical data | |
Fieldbus: | PROFIBUS PROFIsafe |
Enclosure rating: | IP 67 |
Ambient operating temperature from ... to: | 0 C ... 55 C |
Protection class: | III |
Weight: | 620 g |
Safety integrity level: | SIL3 (IEC 61508) |
Category: | Category 4 (EN ISO 13849) |
Performance level: | PL e (EN ISO 13849) |
PFHd: | 1.33 * 1E-09 |
TM (Mission Time): | 20 a |
Supply voltage: | 19.2 V DC, 24 V DC, 28.8 V DC |
Maximum power consumption: | ≤ 9 A |
Number of safety inputs: | 8 dual-channelor 16 single-channel |
Input voltage HIGH field signal inputs: | 11 V, 24 V, 28.8 V |
Input delay field signal inputs: | Configurable 0 ... 90 ms |
Number of test/signal outputs (with current monitoring): | ≤ 16 (2) |
Number of SDL connections: | 2 |
Output voltage HIGH field signal outputs: | UV, without load, switched-on |
Output current field signal output: | 0 mA ... 700 mA |
Minimum current for fault monitoring: | 7 mA ... 40 mA, on field-signal connections 7 and 8 1) |
Maximum current SDL connections: | 1.4 A |
Maximum internal resistance SDL connections (power supply): | 0.3 Ω |
Input voltage HIGH SDL connections (OSSD inputs): | 13 V, 24 V, 28.8 V |
Maximum test puls rate SDL connections (OSSD inputs): | 500 Hz |
Maximum test pulse width SDL connections (OSSD inputs): | 700 s |
Baud rate PROFIBUS connection: | 9.6 kbit/s ... 12 Mbit/s |
Address range PROFIBUS connection: | 3 ... 125 |
Ident numberPROFIBUS: | 071A hex |
1) Only when the connection is configured as an output for a muting lamp. |