Add To Cart
share
Sick UE4457-03DC9F0 Overview
UE4457-03DC9F0: IP67 safety remote controller, 6 dual-channel safety- capable inputs, 12 test/signal outputs an 2 dual-channel bipolar safety outputs, 32 free configurable function blocks. With two (2) SDL connectors for intelligent interfacing.
Sick UE4457-03DC9F0 Description
- Functions as a safety controller or remote I/O
- Six dual-channel or 12 single-channel safety inputs on the device
- Optimized system reaction time in stand-alone or networked operation
- Remote module up to enclosure rating IP 67
- Wide selection of certified function blocks
- Modular expandability and remote I/O reduce costs and provide maximum network flexibility
- Stand-alone mode - without a safety controller - provides increased user flexibility
- Cost-efficient safety solutions by using a safety-enable-standard PLC that controls the safety outputs of the UE4457 no additional safety controller is required
- Reduced implementation costs using safety automation devices without a control cabinet
- Saves space and simplifies installation smaller safety distances between protective devices and hazardous point via the Fast-Shut-Off functionality
- Easy integration and advanced diagnostics of intelligent safety sensors via SICK Safety Data Link (SDL)
Your benefits
| Applications | |
| Safety command devices: | ![]() |
| Electro-mechanical safety switches: | ![]() |
| Non-contact safety switches: | ![]() |
| Opto-electronic protective devices: | ![]() |
| Two-hand control systems: | ![]() |
| Operating mode selector switch: | ![]() |
| Muting sensors: | ![]() |
| Muting lamp: | ![]() |
| Functions | |
| Safedevice communication via EFI/SDL: | ![]() |
| External device monitoring: | ![]() |
| Reset/restart: | Manual / automatic / configurable |
| Logical functions: | AND, NOT, OR, XNOR, XOR |
| On-delay: | ![]() |
| Off-delay: | ![]() |
| Door monitoring: | ![]() |
| Signal routing: | ![]() |
| Bidirectional communication: | ![]() |
| Technical data | |
| Fieldbus: | DeviceNet Safety |
| Enclosure rating: | IP 67 |
| Ambient operating temperature from ... to: | -10 C ... 55 C |
| Protection class: | III (EN 61140) |
| Weight: | 650 g |
| Safety integrity level: | SIL3 (IEC 61508) |
| Category: | Category 4 (EN ISO 13849) |
| Performance level: | PL e (EN ISO 13849) |
| PFHd: | 5.4* 1E-10 |
| TM (Mission Time): | 20 a |
| Supply voltage: | 19.2 V DC, 28.8 V DC |
| Maximum power consumption: | ≤ 4 A ... , per connection 1) |
| Connection type supply voltage: | Mini 7/8" 4 |
| Number of safety inputs: | 6 dual-channel or 12 single-channel |
| Input voltage HIGH field signal inputs: | 11 V DC, 30 V DC |
| Input delay field signal inputs: | Configurable 0 ... 635 ms |
| Number of test/signal outputs (with current monitoring): | 12 |
| Type of output test/signal outputs: | PNP semiconductor |
| Output current test/signal outputs: | 700 mA |
| Number of safe outputs: | 2 dual-channel |
| Type of output safety capable outputs: | bipolar type |
| Maximum switching current safety capable outputs: | 2 A |
| Number of SDL connections: | 2 |
| Maximum number of safety target connections: | 6 |
| DeviceNet communication rate: | 125 kbit/s, 250 kbit/s, 500 kbit/s, Autobaud detection |
| Connection type DeviceNet: | Mini 7/8" 5 |
| 1) Class 2 | |