Add To Cart
share
Sick UP56-214118 Overview
ULTRASONIC SENSOR
Sick UP56-214118 Description
- Non-contact level measurement up to 3.4 m operating distance / 8.0 m limit scanning distance
- Pressure resistant up to 6 bar (87 psi)
- Transducer protected by PVDF cover for increased resistance
- 3-in-1: continuous level measurement, level switch and display
- Analog output switchable between 4 mA ... 20 mA and 0 V 10 V
- Process connector thread G 1 and G 2
- IP 67 enclosure rating
- Easy to set parameters, also via connect+
- Non-contact measurement in pressurized containers - no wear over time
- Easy to set parameters, saving time
- Flexible measurement system for different container sizes - standardization and stock reduction
- One product for point level and continuous applications, reduces the number of sensors required
Your benefits
Features | |
Limiting scanning distance: | 350 mm ... 8,000 mm 1) |
Medium: | Fluids, bulk solids |
Measurement: | switch, continuous |
Operating distance: | 350 mm ... 3,400 mm |
Process pressure: | 0 bar ... 6 bar, gauge pressure |
Process temperature: | -25 C ... 70 C |
1) At 6 bar gauge | |
Performance | |
Repeatability: | 0.15 % 1) |
Resolution: | 0.18 mm |
Accuracy of sensor element: | ≤ 2 % 2) |
1) 2) Of final value | |
Mechanical data | |
Housing material: | Stainless steel 1.4571, PBT, TPU |
Process connection: | G 2 A PN 6 |
Weight: | 1,200 g |
Electrical data | |
Supply voltage: | 9 V DC ... 30 V DC 1) |
Residual ripple: | 10 % |
Power consumption: | ≤ 80 mA 2) |
Output signal: | 1x PNP |
Hysteresis: | 50 mm |
Analog output: | Qa: 4 mA ... 20 mA / 0 ... 10 V 3) 4) |
Connection type: | M12x1, 5-pin |
Response time: | ≤ 240 ms |
Signal voltage HIGH: | Uv - 3 V |
Switching frequency: | 3 Hz |
Enclosure rating: | IP 67 |
Ultrasonic frequency: | 120 kHz |
Time delay before availability: | ≤ 300 ms |
1) Reverse-polarity protected 2) At 24 V without output load 3) Short-circuit protected, reversible 4) Automatic switching between voltage and current outputs dependet on load 4 mA ... 20 mA: RL ? 100/ at 9 V ? UB ?20 V; RL ? 500/ at UB ? 20 V; 0 V 10 V: RL ?100 k/at UB ? 15 V, short-circuit protected | |
Ambient data | |
Ambient temperature, operation: | -25 C ... 70 C , PTFE coating, FFKM 1) |
Ambient temperature, storage: | -40 C ... 85 C |
1) Temperature compensation at -25 C ... 50 C, can be switched off |