f Sick WFM180-120P321 (6037836)- A&S Automation Co., Ltd
 
Home / Sensors / Sick Sensor / Sick WFM180-120P321 (6037836)

Add To Cart
share


Sick WFM180-120P321 Overview



WFM180-120P321 Redlight Forksensor Forkwidth/-depth 180/120mm, PNP, darkswitching M8 3pin

Sick WFM180-120P321 Description



  • Highly visible red emitted light
  • No setup, out-of-the-box operation
  • 360 output indicator
  • 5 fork sizes: maximum depth 120 mm, maximum width 180 mm
  • Rugged, IP 67 aluminum housing
  • Your benefits

  • Fixed housings guarantee a high level of operational safety with simple commissioning
  • A visible red light enables easy alignment and fast adjustment
  • The 360-degree yellow output indicator makes continual process control possible
  • A wide range of different fork sizes increases installation flexibility
  • The aluminum housing meets all requirements for use in harsh industrial conditions

Features
Functional principle:Optical detection principle
Fork width:180 mm
Fork depth:124 mm
MDO 1):1 mm
Label detection:-
Light source:LED, red
Adjustment:None
Switching mode:Darkswitching
1) Minimum detectable object
Mechanics/electronics
Supply voltage Vs 1):DC 10 V ... 30 V
Residual ripple 2):< 10 %
Power consumption 3):< 20 mA
Switching frequency 4):4 kHz
Response time 5):125 s
Stability of response time: 15 s
Switching output:PNP: HIGH = VS -≤ 1.5 V / LOW = 0 V
NPN: HIGH = approx.VS / LOW ≤ 1.5 V
Switching output:PNP
Output current Imax.:100 mA
Initialization time:140 ms
Connection type:Connector M8, 3-pin
Ambient light safety:
Sunlight: 10,000
Protection class 6):III
Circuit protection:VS connections reverse-polarity protected
Output Q short-circuit protected
Interference suppression
Enclosure rating:IP 67
Weight:Ca. 80 g ... 190 g 7)
Housing material:Aluminum
1) Limit values, reverse-polarity protected, operation in short-circuit protected network, max. 8 A 2) May not exceed or fall short of VS tolerances 3) Without load 4) With light/dark ratio 1:1 5) Signal transit time with resistive load 6) Reference voltage DC 50 V 7) Depending on fork width
Ambient data
Ambient temperature 1):Operation: -10 ... 60 C
Storage: -40 ... 80 C
Shock load:according to IEC 60068
1) Do not bend below 0 C