Sick WL24-2V530S06 Overview
Photoelectric Proximity Switch WL24-2V530S06 We would like to point out relating to the Directive 94/9/EC (ATEX) and EN13980 that you are responsible for the traceability of the ordered devices fot your customer (documentation of your customer's data and
Sick WL24-2V530S06 Description
- Marking: EX II 3D IP67 T70C, EX II 3G EEx nA II T4 X according to Directive 94/9/EC (ATEX)
- Corresponds to 3D/3G category
- Large scanning range
- Red
- M12 plug or M16 screw connection: rotatable about 90
- Durable zinc die-cast housing
- High level of operating reserves
- Metal housing for very high resistance and a long service life
- Flexible in installation thanks to rotatable connector concept
Your benefits
Features | |
Dimensions (W x H x D):: | 38 mm x 154.5 mm x 77 mm |
Sensing range max.: | 0 m ... 22 m 1) |
Sensing range: | 0 mm ... 15 mm 2) |
Housing desig (light emission): | Cuboid |
Light source: | LED 3) |
Type of light: | visible red light |
Sensitivity adjustment: | Sensitivity adjustment |
Sensor/detection principle: | Photoelectric retro-reflective sensor |
Light spot (distance): | 250 mm (15 m) |
1) 2) PL80A 3) Average service life 100,000 h at Ta = +25 C | |
Mechanics/electronics | |
Enclosure rating: | IP 67 |
Supply voltage: | 10 V DC ... 30 V DC 1) |
Residual ripple: | < 5 Vpp 2) |
Power consumption: | ≤ 50 mA 3) |
Switching output: | NPN, light/dark-switching, selectable via NPN/PNP selector PNP, light/dark-switching, selectable via light/dark selector |
Output current Imax.: | 100 mA |
Response time: | ≤ 500 s 4) |
Switching frequency: | 1,000 Hz 5) |
Connection type: | Connector M12, 5-pin 6) |
Protection class: | II 7) |
Circuit protection: | A C D 8) 9) 10) |
Weight: | 800 g |
Housing material: | Zinc diecast |
Ambient temperature, operation: | -20 C ... 50 C |
Ambient temperature, storage: | -40 C ... 75 C |
Test input sender off: | TE to 0 V |
Polarisation filter: | ![]() |
Special device: | ![]() |
Front screen heating: | - |
Ex marking (ATEX): | EX II 3D IP67 T70, EX II 3G EEx nA II T4 X according to directive 94/9/EG (ATEX) |
Hazardous area category: | 3D, 3G |
1) Limit values 2) May not exceed or fall short of VS 3) Without load 4) Signal transit time with resistive load 5) With light/dark ratio 1:1 6) Connection rotable by 90 7) Reference voltage 50 V DC 8) A = VS connections reverse-polarity protected 9) C = interference suppression 10) D = outputs overcurrent and short-circuit protected |