Sick WL24-2V530S06 Overview



Photoelectric Proximity Switch WL24-2V530S06 We would like to point out relating to the Directive 94/9/EC (ATEX) and EN13980 that you are responsible for the traceability of the ordered devices fot your customer (documentation of your customer's data and

Sick WL24-2V530S06 Description



  • Marking: EX II 3D IP67 T70C, EX II 3G EEx nA II T4 X according to Directive 94/9/EC (ATEX)
  • Corresponds to 3D/3G category
  • Large scanning range
  • Red
  • M12 plug or M16 screw connection: rotatable about 90
  • Durable zinc die-cast housing
  • Your benefits

  • High level of operating reserves
  • Metal housing for very high resistance and a long service life
  • Flexible in installation thanks to rotatable connector concept

Features
Dimensions (W x H x D)::38 mm x 154.5 mm x 77 mm
Sensing range max.: 0 m ... 22 m 1)
Sensing range: 0 mm ... 15 mm 2)
Housing desig (light emission):Cuboid
Light source:LED 3)
Type of light:visible red light
Sensitivity adjustment:Sensitivity adjustment
Sensor/detection principle:Photoelectric retro-reflective sensor
Light spot (distance):250 mm (15 m)
1) 2) PL80A 3) Average service life 100,000 h at Ta = +25 C
Mechanics/electronics
Enclosure rating:IP 67
Supply voltage:10 V DC ... 30 V DC 1)
Residual ripple:< 5 Vpp 2)
Power consumption:≤ 50 mA 3)
Switching output:NPN, light/dark-switching, selectable via NPN/PNP selector
PNP, light/dark-switching, selectable via light/dark selector
Output current Imax.:100 mA
Response time:≤ 500 s 4)
Switching frequency:1,000 Hz 5)
Connection type:Connector M12, 5-pin 6)
Protection class:II 7)
Circuit protection:A
C
D 8) 9) 10)
Weight:800 g
Housing material:Zinc diecast
Ambient temperature, operation:-20 C ... 50 C
Ambient temperature, storage:-40 C ... 75 C
Test input sender off:TE to 0 V
Polarisation filter:
Special device:
Front screen heating:-
Ex marking (ATEX):EX II 3D IP67 T70, EX II 3G EEx nA II T4 X according to directive 94/9/EG (ATEX)
Hazardous area category:3D, 3G
1) Limit values 2) May not exceed or fall short of VS 3) Without load 4) Signal transit time with resistive load 5) With light/dark ratio 1:1 6) Connection rotable by 90 7) Reference voltage 50 V DC 8) A = VS connections reverse-polarity protected 9) C = interference suppression 10) D = outputs overcurrent and short-circuit protected


Hot Products