Add To Cart
share
Sick WL260-0230501 Overview
Photoelectric Reflex Switch WL260-0230S01
Sick WL260-0230501 Description
- High operating reserve provides increased reliability
- Configuration controls are protected by a cover, ensuring less damage and a longer service life
- Easily accessible terminal chamber for electrical connections simplifies installation
- Simplified integration due to mounting compatibility since variants for DC or DC/AC voltage supply are available in the same design
- Polarizing filter ensures reliable detection, even with shiny targets
Your benefits
Features | |
Dimensions (W x H x D):: | 25 mm x 78 mm x 63 mm |
Sensing range max.: | 0.01 m ... 15 m 1) |
Sensing range: | 0.01 m ... 10 m 0.01 m ... 13 m 2) 3) |
Housing desig (light emission): | Cuboid |
Light source: | LED 4) |
Type of light: | visible red light |
Sensitivity adjustment: | Potentiometer, 270 |
Sensor/detection principle: | Photoelectric retro-reflective sensor |
Light spot (distance): | 300 mm (10 m) |
1) 3) PL80A 2) P250 4) Average service life 100,000 h at Ta = +25 C | |
Mechanics/electronics | |
Enclosure rating: | IP 66 |
Supply voltage: | 20 V AC/DC ... 30 V AC/DC 1) |
Power consumption: | ≤ 70 mA 2) |
Switching output: | Relay, light switching, NO 3) |
Response time: | ≤ 20 ms |
Switching frequency: | 25 Hz 4) |
Connection type: | Cable gland |
Protection class: | II 5) |
Circuit protection: | A C 6) 7) |
Weight: | 120 g |
Housing material: | ABS |
Optics material: | PMMA |
Ambient temperature, operation: | -20 C ... 55 C |
Ambient temperature, storage: | -30 C ... 70 C |
Polarisation filter: | ![]() |
Items supplied: | mounting bracket BEF-W260, Reflector P250 |
Special device: | ![]() |
Angle of dispersion: | 1.7 |
Special features: | two relays with two contacts in serial, test point |
Switching current (switching voltage): | 2 A |
Usage category: | AC-15, DC-13, according to EN 60947-1 |
1) Limit values 2) Without load 3) Provide suitable spark supression for inductive or capacitive loads 4) With light/dark ratio 1:1 5) Rated voltage 250 V AC/DC 6) A = VS connections reverse-polarity protected 7) C = interference suppression |