Add To Cart
share
Sick WL27-3P2460S14 Description
- High scanning range, high operating reserves
- Faster alignment with red light
- Reliable operation in industrial environments and when devices are mounted opposite one another
- Front screen heating, time functions
- Operating temperature: -40 C - +60 C
- UL approval
- Less downtime plus resistance to contamination due to high operating reserves
- Flexible usage due to extended functionality e.g. time functions
- Extremely vibration resistant and therefore largely independent of ambient conditions
- For use at temperatures as low as 40 C
- Highly stable housing due to offset fixing holes
Your benefits
Features | |
Dimensions (W x H x D):: | 24.6 mm x 80.6 mm x 54 mm |
Sensing range max.: | 0.1 m ... 3 m 1) |
Sensing range: | 0.1 m ... 3 m 2) |
Light source: | PinPoint LED 3) |
Type of light: | visible red light |
Light spot diameter (distance): | 30 mm (3 m) |
Adjustment: | no/fix |
Sensitivity adjustment: | No/fix |
1) 2) PL20A 3) Average service life 100,000 h at Ta = +25 C | |
Mechanics/electronics | |
Enclosure rating: | IP 67 |
Supply voltage: | 10 V DC ... 30 V DC 1) |
Residual ripple: | ≤ 5 Vpp 2) |
Power consumption: | ≤ 35 mA 3) |
Switching output: | PNP, light/dark-switching, Complementary |
Output current Imax.: | ≤ 100 mA |
Response time: | ≤ 2.5 ms 4) |
Switching frequency: | 200 Hz with light/dark ratio 1:1 |
Connection type: | Connector M12, 4-pin |
Number of cores: | 4 |
Protection class: | II 5) |
Circuit protection: | A B C 6) 7) 8) |
Weight: | 100 g |
Housing material: | ABS |
Optics material: | PMMA |
Ambient temperature, operation: | -30 C ... 60 C |
Ambient temperature, storage: | -40 C ... 75 C |
Signal voltage PNP HIGH / LOW: | approx. VS - 2.5 V / 0 V |
Special device: | ![]() |
Special features: | scanning range 3 m |
1) Limit values, operation in short-circuit protected network max. 8 A 2) May not exceed or fall short of VS 3) Without load 4) Signal transit time with resistive load 5) Reference voltage 50 V DC 6) A = VS connections reverse-polarity protected 7) B = inputs and output reverse-polarity protected 8) C = interference suppression |