f Sick WL45-P650 (1008837)- A&S Automation Co., Ltd
 
Home / Sensors / Sick Sensor / Sick WL45-P650 (1008837)

Add To Cart
share


Sick WL45-P650 Overview



Reflex Photoelectric Switch WL45-P650 DC 10...60 V, PNP

Sick WL45-P650 Description



  • Long sensing range
  • Rugged metal housing
  • Optional: Powerful front lens heating
  • Optional test input, time delays and alarm output
  • Variants for 10 - 60 V DC or 24 - 240 V DC / 24 - 240 V AC voltage supply
  • Your benefits

  • A long, 55 m sensing range with a high operating reserve ensures reliable continuous operation
  • Rugged metal housing ensures a long service life in harsh industrial environments
  • Front lens heating prevents condensation for reliable operation in outdoor applications
  • Multiple functions for simpler integration of individual systems
  • Variants DC voltage and universal AC/DC voltage provides installation flexibility due to same housing
  • Easy alignment due to visible red light

Features
Dimensions (W x H x D)::60 mm x 105 mm x 105 mm
Sensing range max.: 1 m ... 55 m 1)
Sensing range: 1 m ... 45 m 2)
Housing desig (light emission):Cuboid
Light source:LED 3)
Type of light:visible red light
Sensitivity adjustment:Potentiometer
Delay time:Adjustable via time delay selector switch: 0.5 ... 12 s
0.015 ... 0.3 s
Time type:Switch on delay
time delay off
ON and OFF delay
Sensor/detection principle:Photoelectric retro-reflective sensor
Light spot (distance):230 mm (16 m)
1) 2) OP60-00 3) Average service life 100,000 h at Ta = +25 C
Mechanics/electronics
Enclosure rating:IP 65
Supply voltage:10 V DC ... 60 V DC 1)
Residual ripple:≤ 5 Vpp 2)
Power consumption:≤ 250 mA 3)
Switching output:PNP, light/dark-switching, Complementary
Output current Imax.:200 mA
Response time:≤ 1.2 ms 4)
Switching frequency:400 Hz 5)
Connection type:Connector Hirschmann, 6-pin
Protection class:I 6)
Circuit protection:A
C
D 7) 8) 9)
Weight:800 g
Ambient temperature, operation:-25 C ... 55 C 10)
Ambient temperature, storage:-40 C ... 70 C
Test input sender off:TE to 0 V
Polarisation filter:
Output state-LED:
Front screen heating:
Alarm output:100 mA, open collector 11)
1) Limit values 2) May not exceed or fall short of VS 3) Without load 4) Signal transit time with resistive load 5) With light/dark ratio 1:1 6) Reference voltage 50 V DC 7) A = VS connections reverse-polarity protected 8) C = interference suppression 9) D = outputs overcurrent and short-circuit protected 10) Up to 140 C with cooling plates (see accessories) 11) Flashes at approx. 5 Hz, switch to VS