Add To Cart
share
Sick WL9G-3P1132P10 Description
- High-performance clear material retro-reflective sensor in ultra-rugged VISTAL housing
- Best-in-class optical performance for transparent object detection
- Continuous threshold adjustment
- PinPoint LED for highly visible and precise light spot
- Variable mounting with M3 hole pattern
- Wide range of connection options
- Rugged VISTAL housing provides reliable installation and operation
- Best-in-class optical performance for transparent object detection
- Quick and easy alignment due to the highly visible PinPoint light spot
- M3 slotted hole mounting for multiple mounting possibilities
- One housing with a wide variety of options makes machine integration easy
- Variety of accessories for simple mounting
Your benefits
Features | |
Dimensions (W x H x D):: | 12.2 mm x 50 mm x 23.6 mm |
Sensing range max.: | 0 m ... 5 m 1) |
Sensing range: | 0 m ... 3 m 2) |
Housing desig (light emission): | Cuboid |
Light source: | PinPoint LED 3) |
Type of light: | visible red light |
Wave length: | 650 nm |
Sensitivity adjustment: | Teach |
Teach-in: | single teach button |
Sensor/detection principle: | Photoelectric retro-reflective sensor, autocollimation |
Light spot (distance): | 45 mm (1.5 m) |
1) 2) PL80A 3) Average service life 100,000 h at Ta = +25 C | |
Mechanics/electronics | |
Enclosure rating: | IP 66 IP 67 IP 69K |
Supply voltage: | 10 V DC ... 30 V DC 1) |
Residual ripple: | < 5 Vpp 2) |
Power consumption: | ≤ 20 mA 3) |
Switching output: | PNP, light/dark-switching 4) |
Output current Imax.: | ≤ 100 mA 5) |
Response time: | < 0.5 ms 6) |
Switching frequency: | 1,000 Hz 7) |
Connection type: | Cable, 4-wire, 2 m 8) |
Cable material: | PVC |
Conductor cross-section: | 0.14 mm2 |
Protection class: | III |
Circuit protection: | A B C 9) 10) 11) |
Weight: | 80 g |
Housing material: | VISTAL |
Optics material: | PMMA |
Ambient temperature, operation: | -40 C ... 60 C |
Ambient temperature, storage: | -40 C ... 75 C |
Polarisation filter: | ![]() |
Items supplied: | Reflector PL40, 1 mounting bracket BEF-WN-W9-2 |
Special Design: | for transparent objects |
1) Limit values, operation in short-circuit protected network max. 8 A 2) May not exceed or fall short of VS 3) Without load 4) Q = light-switching 5) As of Tu 50 C, a max. load current Ilmax. = 50 mA is permitted 6) Signal transit time with resistive load 7) With light/dark ratio 1:1 8) Do not bend below 0 C 9) A = VS connections reverse-polarity protected 10) B = inputs and output reverse-polarity protected 11) C = interference suppression |