f Sick WT24-2X200 (1041910)- A&S Automation Co., Ltd
 
Home / Sensors / Sick Sensor / Sick WT24-2X200 (1041910)

Add To Cart
share




Sick WT24-2X200 Overview



PHOTOE.PROX.SWITCH

Sick WT24-2X200 Description



  • Classification: EX II 2G Ex ia op is IIC T4 according to Directive 94/9/EC (ATEX)
  • Corresponds to Category 2G
  • Output type: EN 60947-5-6 (NAMUR)
  • Long sensing range with very precise background suppression
  • M12 or terminal chamber connection: 90 rotatable
  • Durable metal housing
  • Your benefits

  • Allows longer sensing range despite the limited factors of the norms for Category 2G (ATEX, explosive environments)
  • Metal housing that has been IP 69K tested provides reliability and a long service life
  • Flexible installation due to 90 rotatable connector

Features
Dimensions (W x H x D)::27 mm x 87.5 mm x 65 mm
Sensing range max.: 40 mm ... 2,000 mm 1)
Sensing range: 100 mm ... 2,000 mm
Housing desig (light emission):Cuboid
Light source:LED 2)
Type of light:Infrared light
Adjustment of operating distance:Potentiometer
Sensor/detection principle:Photoelectric proximity sensor, Background suppression
Light spot (distance):50 mm (2,000 mm)
1) Object with 90 % reflectance (referred to standard white DIN 5033) 2) Average service life 100,000 h at Ta = +25 C
Mechanics/electronics
Enclosure rating:IP 67
Supply voltage:5 V DC ... 15.5 V DC 1)
Residual ripple:< 0.4 Vpp 2)
Switching output:NAMUR, light switching
Response time:≤ 10 ms 3)
Switching frequency:50 Hz 4)
Connection type:Terminal connection with M16 gland 5)
Protection class:II 6)
Circuit protection:A
C 7) 8)
Weight:330 g
Housing material:Zinc diecast
Optics material:glass
Ambient temperature, operation: -20 C ... 60 C
Ambient temperature, storage:-25 C ... 70 C
Front screen heating:-
EC type approval certificate:PTB 03 ATEX 2105
Ex marking (ATEX):II 2G Ex ia op is IIC T4 according to directive 94/9/EG (ATEX)
Hazardous area category:2G
Input voltage Ui max:15.5 V 9)
Input power Pimax.:100 mW 10)
Input current Ii max:53 mA 11)
Internal capacitance Ci max.:80 nF 12)
Internalinductance Li max.:0 H 13)
1) Limit values, supply with switching amplifier EN2Ex (internal resistor approx. 1 kOhm) 2) May not exceed or fall short of VS 3) Signal transit time with resistive load 4) With light/dark ratio 1:1 5) Connection rotable by 90 6) Reference voltage 50 V DC 7) A = VS connections reverse-polarity protected 8) C = interference suppression 9) 10) 11) 12) 13) For connection to a sperately certified intrinsically safe circuit only