Home / Sensors / Gefran Sensor / Thermocouples-Resistance Thermometers / Gefran AC9 Thermocouples for the Steel Industry

Add To Cart
share
DESCRIPTION:
Amplified output signal
Temperature limits:
-40 ... +1200C for type K
0 ... +1400C for types S and R
+600 ... +1600C for type B
(see table for sheath diameters)
Tolerance (IEC standard 584.2/Class 1):
for type K:
2.5 C (- 40 ... + 333 C)
0.0075 x [t] (t > + 333 C)
for type S, R,
1 C 0...+1100
[1+0,003 x (t -1100)]C +1100...+1600C
for type B:
+600 C ... + 1700C
0.0025 x [t]
Ceramic insulation of the thermocouple element
Application versatility