OPTEX Photoelectric Sensors V3/V4 Series
Features:
?Easy and quick disconnection for quick maintenance.Simply remove the main body from the base to replace the sensor.
?Long sensing distance - 40 meters thru-beam.
?Terminal connection(AC types - V4 series).
Application:
Stable detection of cars in a dusty environment is available due to its big lens even if it gets contaminated.
Model
Relay output type
Transistor output type
Thru-beam
Retro-reflective
Diffuse reflective
Thru-beam
Retro-reflective
Diffuse reflective
V3 series (cable/QD type)
V3T-4000
V3R-1000
V3D-130
V3T-4000N, P, CN, CP
V3R-1000N, P, CN, CP
V3D-130N, P, CN, CP
V4 series (terminal type)
V4T-4000
V4R-1000
V4D-130
V4T-4000N, P, CN, CP
V4R-1000N, P, CN, CP
V4D-130N, P, CN, CP
Maintenance unit
(common to V3/V4)
US-34 (emitter)
UE-34 (receiver)
UR-34
UD-34
US-34D (emitter)
UE-34N or 34P (receiver)
UR-34N or 34P
UD-34N or 34P
Sensing distance
40m
0.01 - 10m
1.3m
40m
0.01 - 10m
1.3m
Response time
20msec
0.5 msec
Operating mode
Light ON
Light ON / Dark ON switchover
Hysteresis
NIL
20% Max
NIL
20% Max
Light source
Red
Indicator
Single LED (Orange) as output indicator
Single LED (Orange) as output indicator
Control output
Relay NO/NC 240V AC / 30 VDC, 3A
NPN or PNP
Supply voltage
AC/DC 24-240V, +/- 10% ripple
10 - 30V DC including +/- 10% ripple
Conformity
JIS/C4525, CE, UL
Power consumption
9.5VA
5VA
40mA without load
Connection : V3 series
2 meter cable
2 meter cable, or M12 QD
Connection : V4 series
Terminal chamber, applicable cable ?6 to ?10
Terminal chamber, applicable cable ?6 to ?10
Operating temp
?25 to 55 oC
Operating humidity
35 to 85 % RH
Storage temp
?40 to 70 C / 35 - 95% RH
Sensitivity adjustment
Single turn pot.
Protection category
IEC 144, IP66
Shock resistance
50G , XYZ 3-ways
Materials
Glassfiber reinforced ABS (Case), PMMA (Lens)