Multiple light beam safety devices are electro-sensitive protective solutions with two or more light beams. They comply with type 4 and/or type 2 in acc. with IEC 61496, and PL e and/or PL d in acc. with EN ISO 13849. If one or more of the beams is interrupted, a deactivation signal is sent to the machine so that any dangerous state on a machine or system can be stopped. A system consists of a sender and a receiver. In active/passive systems, the sender and receiver are located in a housing unit while a deflection unit on the passive side provides beam deflection.
Complete function spectrum (muting)
M4000 Advanced and M4000 Advanced A/P
Intelligent and efficient: connection of the muting signals directly on site
Type 4 (IEC 61496), PL e (EN ISO 13849)
Robust housing with three mounting grooves
7-segment display
Wide scanning range, up to 70 m
External device monitoring (EDM), restart interlock (RES), application diagnostic output (ADO), SDL interface
Muting in combination with the UE403 switching amplifier
Laser alignment aid and LED optional integrated
Configuration and diagnostics via PC