Add To Cart
share
Pressure type:Gauge pressure
Measurement range:0 bar ... 100 bar
Process temperature:-30 °C ... 100 °C
Output signal:4 mA ... 20 mA, 2-wire
Maximum ohmic load RA:≤ (L+ - 7 V) / 0.02 A [Ohm] with current output signal
Performance
Accuracy: ≤ ± 1.2 % of span (at room temperature)
Non-linearity: ≤ ± 0.5 % of span (best fit straight line, BFSL)
Response time: < 2 ms
Long-term drift/one-year stability: ≤ ± 0.3 % of span (per year)
Temperature error: ≤ ± 1.5 % of span
Rated temperature range: 0 °C ... 80 °C
Service life: Minimum 10 Mio. life cycles
Measurement deviation of zero signal: ≤ ± 0.5 % of span