Add To Cart
share
Sick LUT3-951 Overview
Luminescense Scanner LUT3-951 NPN,PNP switching output, scanning distance 50 mm off-delay, analogue output plug M 12, 5pin filter og570
Sick LUT3-951 Description
- High system sensibility
- Scanning distance selectable by using interchangeable lenses (10 ... 90 mm)
- Fibre-optic cable connection
- Analogue output
- Additional optical filter
Features | |
Dimensions (L x W x H): | 80 mm x 30.4 mm x 53 mm |
Sensing distance 1): | 50 mm |
Light source 2) 3): | UV-LED |
Light spot size: | 5 mm x 15 mm |
Receiving filters: | OG 570 |
Receiving range: | 570 nm ... 750 nm |
Adjustment: | Manual (potentiometer) |
Switching mode: | Light switching |
1) From front edge of lens 2) Average service life of 100,000 h at TA = +25 C 3) Wave length: 375 nm | |
Mechanics/electronics | |
Supply voltage Vs: | DC 12 V ... 30 V |
Residual ripple 1): | < 2 Vpp |
Power consumption 2): | < 60 mA |
Switching frequency 3): | 1.5 kHz |
Response time 4): | 350 s |
Switching output: | PNP: HIGH = VS-≤3 V / LOW = approx. 0 V NPN: HIGH = approx.VS/ LOW ≤ 2 V |
Switching output: | PNP/NPN |
Output current Imax.: | 100 mA |
Electrical connection: | Connector M12, 5-pin |
Protection class 5): | II |
Circuit protection: | Output Q short-circuit protected Interference suppression VS connections reverse-polarity protected |
Enclosure rating: | IP 67 |
Weight: | Ca. 400 g |
Housing material: | Die-cast zinc |
1) May not exceed or fall short of VS tolerances 2) Without load 3) With light/dark ratio 1:1 4) Signal transit time with resistive load 5) Reference voltage 50 V DC Limit values: operation in short-circuit protected network max. 8 A | |
Ambient data | |
Ambient temperature: | Operation: -10 ... 55 C Storage: -25 ... 75 C |
Shock load: | according to IEC 60068 |