The
SITRANS F US SONO 3100/SITRANS FUS060 flowmeter consists of a SITRANS F US SONO
3100 sensor with O-ring or flange transducers depending on the application. The
standard version is delivered as a 2-track sensor with or without flanges; 4
tracks are available upon request. Available pipe materials include carbon or
stainless steel. The SITRANS FUS060 transmitter is engineered for high
performance applications and designed for remote installation in hazardous as well
as non-hazardous environments. In addition to the standard outputs, it also
offers communication.
The
SITRANS F US SONO 3100/SITRANS FUS060 flowmeter consists of a sensor and
transmitter. For details and information about the transmitter, see SITRANS FUS060
Application
Examples: Oil, Cryogenic liquids, Power engineering, Cold- , Hot- and
Waste water.
Detail
Meassuring range
Qn 28 to 13200 m3/h (depends on size)
Nominal size
From DN 100 to DN 1200 (4" to 48")
Accuracy
0.5% of flow rate
Operational pressure
Max. 430 bar (Max. 6235 psi)
Operating temperature
From -20 to 85 C (-4 to 185 F)
Medium temperature
From -200 to 200 C (-328 to 392 F)
Design
2 track (on request up to 4 tracks)
Material
Stainless steel and carbon steel
Approval
ATEX
Benefits
Ideal flowmeter system for challenging applications
within the oil flow, distribution and on/offshore industries
Easy exchange of integrated transducers without the need
for downtime or process shutdown
Optimal solution for fiscal metering as it meets
OIML R117 requirements
Designed for remote installation in hazardous as well as
non-hazardous environments