Home / Sensors / IFM Sensor / Capacitive Position Sensors / IFM Capacitive Position Sensors M30 Hazardous Use
Add To Cart
share
Capacitive
sensors for hazardous area applications
Sensors and amplifiers for hazardous locations
Capacitive sensors in tubular housings
Single and dual channel switching amplifiers
available in AC and DC operating voltage
FM, CSA and ATEX approved for hazardous locations
2m cable with PVC jacket
Product characteristics | ||||
Capacitive sensor | ||||
Plastic thread M30 x 1.5 | ||||
Cable | ||||
ATEX approval | ||||
Group II, category 1D/1G | ||||
Sensing range 15 mm; adjustable; [nf] non-flush mountable | ||||
Electrical data | ||||
Electrical design | Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW | |||
Nominal voltage [V] | 8.2 DC; (1k) | |||
Supply voltage [V] | 7.5...15 DC | |||
Current consumption [mA] | < 1 *) | |||
Protection class | II | |||
Outputs | ||||
Output function | normally closed | |||
Switching frequency [Hz] | 40 | |||
Monitoring range | ||||
Sensing range [mm] | 15 | |||
Real sensing range (Sr) [mm] | 15 10 % | |||
Accuracy / deviations | ||||
Correction factors | water = 1 / glass approx. 0.4 / ceramics approx. 0.2 / PVC approx. 0.2 | |||
Hysteresis [% of Sr] | 1...15 | |||
Switch-point drift [% of Sr] | -15...15 | |||
Environment | ||||
Ambient temperature [C] | -20...60 | |||
Protection | IP 65 | |||
Tests / approvals | ||||
Approval | DMT 01 ATEX E 020 TIIS TC15627 IECEx BVS 06.0003 | |||
Marking of the unit | II 1G EEx ia IIB T6 II 1D Ex iaD 20 T90C | |||
EMC |
|