OPTEX Displacement Sensors CD1 Series
Features:
As small as the best dimensions for Built-in use for OEM machine.
Versatility from 30+/-4mm to 250+/-150mm distance.
Both transistor and analogue output applicable to digital panel meter if you need display and signal control.
Applications:
Checking mechanical parts Height of mechanical parts can be measured by CD1 easily.
Height of packages of food can be measured by CD1 easily even if it's colored.
Stable measurement of electric components is available by CD1 regardless its material.
Detecting existence of bottle cap at correct position is available by CD1.
CD1 Series, PSD system Laser type Displacement Sensor
Cable
CD1-30N/P
CD1-50N/P
CD1-100N/P
CD1-130N/P
CD1-250N/P
M12 Connector
CD1-30CN/CP
CD1-50CN/CP
CD1-100CN/CP
CD1-130CN/CP
CD1-250CN/CP
Transistor output
N = NPN output, P = PNP output
Measuring range
30+/-4mm
50 +/- 10mm
100 +/- 35mm
130 +/- 50mm
250 +/- 150mm
FS?full scale?
8mm
20mm
70mm
100mm
300mm
Light source
Class 2 Laser, 650nm, Max 3.3mW
Spot size
?0.1mm
?0.5mm
0.5 X 1.2 mm
0.5 X 1.5 mm
0.8 X 1.2 mm
Supply voltage
12 - 24V DC ??5 to ?10%?
Power consumption
Max 120mA ?DC12V?, 75mA ?DC24V?, including analog output current
Resolution?typical value?
?Unit : Micron. Under AUTO sensitivity. White ceramic as an object?
?Response Speed 100msec?
1
3
15
20
150
?Response Speed 10msec?
3
10
50
70
500
?Response Speed 1msec?
10
30
150
200
1500
Linearity
+/- 2% FS
+/-1% FS
+/- 2% FS
+/- 3.5% FS
+/- 5% FS
+/- 5% FS
+/- 0.02% FS/ Celsius
Response time
100msec / 10msec / 1msec selectable
Sensitivity adjustment
SET / FIX / AUTO
Analogue output
4-20mA
Control output
NPN or PNP, Max 100mA/DC30V, Residual Voltage Max 1.8V
Distance indicator
Red = Near, Orange = Middle, Green = Far, Red/Green = Error *Remark : Errors as "out of measuring range", "Too high reflection", etc
Stability indicator
Green = Stable, Red = Error, No light = Unstable, need adjustment
Output indicator
Orange = Output
Teach-in indicator
Green = Input, Red = Error
Blanking input
NPN = Gray wire to 0V, PNP = Gray wire to ?V
Delay function
Off delay 40msec
Environmental illuminance
Sun light : Max 10,000 lux, Incandescent Lamp = Max 3,000 lux
Operating temp
10 to 40C
Operating humidity
35 to 95% RH
Material
Zinc diecast
Protection category
IP67
Conformity
CE
Warm-up time
30 minutes